Background: Image intensifiers have become popular due to the concept of minimally invasive surgeries leading to decreasing invasiveness, decreased operative time, and less morbidity. The drawback, however, is an increased risk of radiation exposure to surgeon, patient and theatre staff. These exposures have been of concern due to their potential ability to produce biological effects. The present study was embarked upon to analyse the amount of radiation received by orthopedic surgeons in India using standard precautionary measures and also to bring awareness about the use of image intensifier safety in everyday practice.

Materials And Methods: Twelve right-handed male orthopedic surgeons (4 senior consultants, 5 junior consultants and 3 residents) were included in a three month prospective study for radiation exposure measurement with adequate protection measures in all procedures requiring C Arm fluoroscopy. Each surgeon was provided with 5 Thermo Luminescent Dosimeter (TLD) badges which were tagged at the level of neck, chest, gonads and both wrists. Operative time and exposure time of each procedure was recorded. Exposure dose of each badge at the end of the study was obtained and the results were analysed.

Results: Mean radiation exposure to all the parts were well within permissible limits. There was a significantly positive correlation between the exposure time and the exposure dose for the left wrist (r=0.735, p<0.01) and right wrist (r=0.58, p<0.05). The dominant hand had the maximum exposure overall.

Conclusion: Orthopaedic surgeons are not classified radiation workers. The mean exposure doses to all parts of the body were well within permissible limits. Nothing conclusive, however, can be said about the stochastic effects (chance effects like cancers). Any amount of radiation taken is bound to pose an additional occupational hazard. It is thus desirable that radiation safety precautions should be taken and exposures regularly monitored with at least one dosimeter for monitoring the whole-body dose.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4413121PMC
http://dx.doi.org/10.7860/JCDR/2015/10520.5672DOI Listing

Publication Analysis

Top Keywords

radiation exposure
16
exposure
8
arm fluoroscopy
8
operative time
8
orthopedic surgeons
8
time exposure
8
exposure time
8
exposure dose
8
occupational radiation
4
exposure arm
4

Similar Publications

Background: Exposure to ionizing radiation is inevitable due to its extensive use in industrial and medical applications. The search for effective and safe natural therapeutic agents as alternatives to chemical drugs is crucial to mitigate their side effects. This study aimed to evaluate the effects of citicoline as a standalone treatment or in combination with the anti-hepatotoxic drug silymarin in protecting against liver injury caused by γ-radiation in rats.

View Article and Find Full Text PDF

Atlantoaxial dislocation (AAD) is a serious condition in which the first two cervical vertebrae lose their anatomical position and stability. This may lead to neurological complications, including death. The treatment of AAD remains controversial, and posterior instrumentation with pedicle screw placement is one of the commonly used methods.

View Article and Find Full Text PDF

Background: Despite patent ductus arteriosus closure in premature infants is a relatively fast procedure, it involves specific steps for equipment exchange and the use of a 4-Fr catheter, which may be large for tiny infants, potentially causing haemodynamic instability or tricuspid valve regurgitation.

Objectives: This study aims to describe the early experience with a new technique designed to simplify transcatheter patent ductus arteriosus closure in premature infants. It enables the closure using the KA micro plug device via a single microcatheter without equipment exchanges and contrast exposure.

View Article and Find Full Text PDF

Photon-counting mammography is an emerging modality that allows for spectral imaging and provides a differentiation of material compositions. The development of photon-counting mammography-specific contrast agents has yet to be explored. In this study, the contrast, sensitivity, and organ dose between silver sulfide nanoparticles (AgS-NPs) and a clinically approved iodinated agent (iopamidol) were investigated using a contrast-embedded gradient ramp phantom and a prototype scanner.

View Article and Find Full Text PDF

The effects of age and other individual factors on radiation induced ESR signals from fingernails.

Front Public Health

January 2025

Department of Radiation Biophysics, Research Institute for Radiation Biology and Medicine (RIRBM), Hiroshima University, Hiroshima, Japan.

Biodosimetry is crucial for assessing ionizing radiation exposure to guide medical responses. Electron spin resonance (ESR) spectroscopy using fingernails can be effectively used for both occupational and public dose assessments in radiological accidents because of their accessibility and ability to retain stable radiation-induced free radicals. However, despite two decades of research, challenges remain in achieving accurate fingernail dosimetry, mainly owing to the variation in ESR signals among individuals.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!