Aim. The aim of this study was to determine the intra- and interobserver variability of two Scheimpflug based camera systems, Pentacam and Sirius. In addition, the comparability of the measurements was tested in healthy subjects, subjects with regular astigmatism, and keratoconus patients. Methods. Intra- and interobserver variability were assessed in 20 healthy corneas. Pachymetry values were also compared with ultrasound pachymetry as a reference measurement. To detect possible differences between the two devices, 82 eyes with clinically established keratoconus, 30 eyes with regular astigmatism (>1.5 D), and 60 eyes without corneal pathologies were included in this prospective study. Results. Pachymetry and keratometry showed good intra- and interobserver variability for both devices. Pachymetry values obtained with the Sirius system (579 ± 58 μm) were significantly higher compared to the Pentacam system (551 ± 40 μm, P < 0.001) and to ultrasound pachymetry (550 ± 43 μm, P < 0.001). Significant interdevice differences were found regarding the majority of the detected keratometry parameters. Conclusions. Both devices show almost perfect reproducibility in healthy subjects. However, pachymetry and keratometry values of the two devices should not be used interchangeably.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4411433PMC
http://dx.doi.org/10.1155/2015/315281DOI Listing

Publication Analysis

Top Keywords

regular astigmatism
12
intra- interobserver
12
interobserver variability
12
healthy corneas
8
healthy subjects
8
pachymetry values
8
ultrasound pachymetry
8
pachymetry keratometry
8
pachymetry
6
devices
5

Similar Publications

Aim: To investigate the effect of astigmatism and spherical equivalent (SE) correction on contrast sensitivity (CS).

Methods: In this cross-sectional study, 103 visually normal subjects aged 18 to 36y with bilateral regular astigmatism in range of 1.00 diopter cylinder (DC) to 4.

View Article and Find Full Text PDF

Artificial intelligence-assisted fitting method using corneal topography outcomes enhances success rate in orthokeratology lens fitting.

Cont Lens Anterior Eye

December 2024

Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai 200031, China; NHC Key laboratory of Myopia and Related Eye Diseases, Key Laboratory of Myopia and Related Eye Diseases, Chinese Academy of Medical Sciences, Shanghai, 200031, China; Shanghai Research Center of Ophthalmology and Optometry, Shanghai 200031, China; Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), China. Electronic address:

Purpose: Based on ideal outcomes of corneal topography following orthokeratology (OK), an innovative machine learning algorithm for corneal refractive therapy (CRT) was developed to investigate the precision of artificial intelligence (AI)-assisted OK lens fitting.

Methods: A total of 797 eyes that had been fitted with CRT lenses and demonstrated good lens centration with plus power ring intact in their topography were retrospectively included. A comprehensive AI model included spherical refraction, keratometry readings, eccentricity, corneal astigmatism, horizontal visible iris diameter, inferior-superior index, surface asymmetry index, surface regularity index and 8-mm chordal corneal height difference.

View Article and Find Full Text PDF

To explore the corrective effect of cataract extraction surgery combined with a 2.8 mm steep-axis corneal incision under ophthalmic surgical navigation on low-to-moderate corneal astigmatism and different types of corneal astigmatism. A prospective cohort study was conducted.

View Article and Find Full Text PDF

Background: Baraitser-Winter syndrome (BWS) is rare, and no previous reports have described the visual course of patients with this condition. Herein, we report the long-term visual outcomes and ocular features of a 6-year-old patient diagnosed with BWS.

Case Presentation: A 6-year-old female patient visited our clinic complaining of low vision.

View Article and Find Full Text PDF
Article Synopsis
  • Trigonocephaly, a condition affecting the shape of the head, is linked to poorer visual outcomes in children, but its impact on orthoptic issues post-visual development is unclear.
  • A study assessed 78 non-syndromic trigonocephaly patients aged 8 and older, finding a significant prevalence of refractive errors and other visual abnormalities compared to healthy peers.
  • Results indicated trigonocephaly patients have a much higher risk for issues like hyperopia, amblyopia, and strabismus, suggesting the need for regular eye screenings and long-term monitoring by specialists.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!