Purpose: Electrocardiographic (ECG) guidance has been shown to be as effective than fluoroscopy to position the tip of central venous devices close to the superior vena cava (SVC)-right atrium (RA) junction. When SVC access is contraindicated, a femoral access may be used. The aim of this prospective study is to evaluate the effectiveness of ECG guidance to position the tip of femoral ports at inferior vena cava (IVC)-RA junction.

Methods: Inclusion criterion was the need for femoral port implantation. After insertion of the dilator in the femoral vein, the catheter with the guide wire inside was introduced and the ECG signal collected at the tip of the guide (Celsite™ ECG, B. Braun, Germany) or via saline injected in the catheter (Nautilus™, Perouse, France). Fluoroscopy was performed at each change of the P-wave from IVC to RA. A final X-ray was performed after withdrawing the catheter 2 cm below the first P-wave change.

Results: A total of 18 patients were included between December 2011 and June 2013. The P-wave was most often negative in IVC, biphasic when the catheter entered RA and giant and positive at the top of RA. When the catheter was withdraw 2 cm below the first biphasic P-wave the tip was just below the IVC-RA junction in 17 patients. In one patient P-wave changes were not significant and the final position was adjusted under fluoroscopy.

Conclusions: ECG guidance is effective to assess catheter tip position during femoral port placement and avoids the need for radiological methods.

Download full-text PDF

Source
http://dx.doi.org/10.5301/jva.5000386DOI Listing

Publication Analysis

Top Keywords

ecg guidance
12
catheter position
8
guidance effective
8
vena cava
8
position femoral
8
femoral port
8
catheter
7
femoral
6
position
5
ecg
5

Similar Publications

An Ovine Model of Chronic Heart Failure Induced by Repeated Coronary Microembolizations.

Methods Mol Biol

December 2024

Manaaki Manawa - The Centre for Heart Research and the Department of Physiology, University of Auckland, Auckland, New Zealand.

The use of large animals in research provides a unique bridge between preclinical findings and clinical relevance, offering a valuable perspective for advancing our understanding of the complexities of heart failure. Multiple models of heart failure have been established with advantages and limitations of each model. Many insights have been gained from these models for understanding both pathophysiological mechanisms and therapeutic interventions for heart failure.

View Article and Find Full Text PDF

3D-targeted, electrocardiographic imaging-aided stereotactic radioablation for ventricular tachycardia storm: a case report.

Eur Heart J Case Rep

October 2024

Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Center+, Postbus 5800, 6202 AZ Maastricht, The Netherlands.

Background: Stereotactic arrhythmia radioablation (STAR) is a promising non-invasive therapy for patients with ventricular tachycardia (VT). Accurate identification of the arrhythmogenic volume, or clinical target volume (CTV), on the radiotherapy (RT) 4D planning computed tomography (CT) scan is key for STAR efficacy and safety. This case report illustrates our workflow of electro-structural image integration for CTV delineation.

View Article and Find Full Text PDF

Background: Heart rate (HR) monitoring is a medical standard to provide information about a patient's health status. In palliative care, relationship and social engagement are crucial therapeutic concepts. For fear of disrupting communication, social contact, and care, continuous HR monitoring is underutilised despite its potential to inform on symptom burden and therapeutic effects.

View Article and Find Full Text PDF
Article Synopsis
  • Premature ventricular beats during pregnancy can lead to serious complications like palpitations, reduced placental blood flow, and risks for the fetus, including miscarriage.
  • A case study highlights the successful use of radiofrequency catheter ablation on a pregnant woman with a rare focus of these beats, demonstrating both the challenges and positive outcomes of the procedure.
  • The use of fluoroscopy-less ablation is beneficial as it minimizes radiation exposure while ensuring a high success rate and safety for pregnant patients.
View Article and Find Full Text PDF

Background: Wellen's syndrome may indicate severe stenosis or even occlusion of the proximal left anterior descending coronary artery. It may progress to acute myocardial infarction. Early recognition and an early invasive strategy are critical to avoiding impending myocardial injury.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!