ESI-MS is a well established technique for the study of biopolymers (nucleic acids, proteins) and their non covalent adducts, due to its capacity to detect ligand-target complexes in the gas phase and allows inference of ligand-target binding in solution. In this article we used this approach to investigate the interaction of ligands to the Heat Shock Protein 90 (Hsp90). This enzyme is a molecular chaperone involved in the folding and maturation of several proteins which has been subjected in the last years to intensive drug discovery efforts due to its key role in cancer. In particular, reference compounds, with a broad range of dissociation constants from 40pM to 100μM, were tested to assess the reliability of ESI-MS for the study of protein-ligand complexes. A good agreement was found between the values measured with a fluorescence polarization displacement assay and those determined by mass spectrometry. After this validation step we describe the setup of a medium throughput screening method, based on ESI-MS, suitable to explore interactions of therapeutic relevance biopolymers with chemical libraries. Our approach is based on an automated flow injection ESI-MS method (AFI-MS) and has been applied to screen the Nerviano Medical Sciences proprietary fragment library of about 2000 fragments against Hsp90. In order to discard false positive hits and to discriminate those of them interacting with the N-terminal ATP binding site, competition experiments were performed using a reference inhibitor. Gratifyingly, this group of hits matches with the ligands previously identified by NMR FAXS techniques and confirmed by X-ray co-crystallization experiments. These results support the use of AFI-MS for the screening of medium size libraries, including libraries of small molecules with low affinity typically used in fragment based drug discovery. AFI-MS is a valid alternative to other techniques with the additional opportunities to identify compounds interacting with unpredicted or allosteric sites, without the need of any binding probes.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejps.2015.05.001DOI Listing

Publication Analysis

Top Keywords

automated flow
8
flow injection
8
injection esi-ms
8
esi-ms method
8
fragment based
8
drug discovery
8
esi-ms
5
establish automated
4
method screening
4
screening fragment
4

Similar Publications

Background: Low-temperature cryopreservation is a common method for scientific research and clinical sample preservation when utilizing flow cytometry. In flow cytometry data analysis, traditional manual "gating" is susceptible to past experience and faces the challenge of manual subjective bias, time-consuming, and multidimensional data analysis. With the development of algorithms, the advantages of dimensionality reduction and clustering in result analysis are gradually becoming more prominent.

View Article and Find Full Text PDF

Introduction: Preoperative identification of the site of rectal cancer surgery is crucial for ensuring accurate tumor localization and resection. Commonly employed methods include contrast-enhanced enterography and endoscopic marking techniques, such as clipping and India ink tattooing. However, India ink tattooing poses challenges, including obstruction of the surgical field, ink leakage into the abdominal cavity, and potential complications such as peritonitis and adhesive bowel obstruction.

View Article and Find Full Text PDF

Objectives: To evaluate urinalysis parameters useful for identifying mixed cultures in urine culture using an automated urinary particle analyzer to assess quality indicators (QIs) for urine sample contamination.

Methods: A retrospective observational cross-sectional study was conducted with 2,527 urine samples from patients of a quaternary hospital in Brazil. Urine samples were processed simultaneously in Sysmex UF-5000 flow cytometry analyzer (urinalysis) and MALDI-TOF (culture).

View Article and Find Full Text PDF

Background: Medical simulation is relevant for training medical personnel in the delivery of medical and trauma care, with benefits including quantitative evaluation and increased patient safety through reduced need to train on patients.

Methods: This paper presents a prototype medical simulator focusing on ocular and craniofacial trauma (OCF), for training in management of facial and upper airway injuries. It consists of a physical, electromechanical representation of head and neck structures, including the mandible, maxillary region, neck, orbit and peri-orbital regions to replicate different craniofacial traumas.

View Article and Find Full Text PDF

Chemotherapy is essential for treating tumors, including head and neck cancer (HNC). However, the toxic side effects of chemotherapeutic drugs limit their widespread use. Therefore, a targeted delivery system that can transport the drug to the pathological site while minimizing damage to healthy tissues is urgently needed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!