The technical and dosimetric aspects are presented of high-dose intracavitary brachytherapy in gynecology. Fifty-five patients (203 insertions) were examined over two years with a remote loading Selectron HDR 60Co unit installed in a dedicated bunker. The dose to the rectal and bladder markers on AP and LL films was calculated before every irradiation, in order to allow the necessary corrections to be made. Uniform irradiation conditions were obtained at each treatment set-up for both tumoral target and bladder and rectal doses. High-dose intracavitary brachytherapy proved to be a safe, reliable and versatile method from the technical and dosimetric point of view both in the treatment of unoperated gynecological malignancies and in postoperative therapy.
Download full-text PDF |
Source |
---|
Biomed Phys Eng Express
January 2025
Radiation Oncology, Emory University, Emory Midtown Hospital, Atlanta, Georgia, 30322, UNITED STATES.
Although radiotherapy techniques are the primary treatment for head and neck cancer (HNC), they are still associated with substantial toxicity, and side effect. Machine learning (ML) based radiomics models for predicting toxicity mostly rely on features extracted from pre-treatment imaging data. This study aims to compare different models in predicting radiation-induced xerostomia and sticky saliva in both early and late stage of HNC patients using CT and MRI image features along with demographics and dosimetric information.
View Article and Find Full Text PDFCureus
December 2024
Physics and Engineering, London Regional Cancer Program, London, CAN.
Introduction: Radiation may unintentionally injure myocardial tissue, potentially leading to radiation-induced cardiac disease (RICD), with the net benefit of non-small cell lung cancer (NSCLC) radiotherapy (RT) due to the proximity of the lung and heart. RTOG-0617 showed a greater reduction in overall survival (OS) comparing higher doses to standard radiation doses in NSCLC RT. VHeart has been reported as an OS predictor in the first- and fifth-year follow-ups.
View Article and Find Full Text PDFMed Phys
January 2025
OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden-Rossendorf, Dresden, Germany.
Background: Previous studies have shown that in-beam magnetic resonance imaging (MRI) can be used to visualize a proton beam during the irradiation of liquid-filled phantoms. The beam energy- and current-dependent local image contrast observed in water was identified to be predominantly caused by beam-induced buoyant convection and associated flow effects. Besides this flow dependency, the MR signal change was found to be characterized by a change in the relaxation time of water, hinting at a radiochemical contribution, which was hypothesized to lie in oxygen depletion-evoked relaxation time lengthening.
View Article and Find Full Text PDFAdv Radiat Oncol
February 2025
Department of Radiation Oncology, Nanfang Hospital, Southern Medical University, Guangzhou, China.
Purpose: The objective of this study was to explore the performance of a predictive model for swallowing-induced breakthrough pain established using a redefined delineation method based on the common occurrence sites of radiation-induced oral mucositis (RIOM) in locally advanced nasopharyngeal carcinoma (NPC).
Methods And Materials: A total of 208 patients with locally advanced NPC were included in the study cohort, and the test cohort consisted of 88 patients. The oral mucosa structure was contoured using oral cavity contour (OCC), mucosal surface contour (MSC), and oral-pharyngeal mucosa (OPM) methods, and relevant dosimetric parameters were collected.
Med Phys
January 2025
OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany.
Background: Patient-specific quality assurance (PSQA) is a crucial yet resource-intensive task in proton therapy, requiring special equipment, expertise and additional beam time. Machine delivery log files contain information about energy, position and monitor units (MU) of all delivered spots, allowing a reconstruction of the applied dose. This raises the prospect of phantomless, log file-based QA (LFQA) as an automated replacement of current phantom-based solutions, provided that such an approach guarantees a comparable level of safety.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!