A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Four petals evisceration for atrophia bulbi. | LitMetric

Four petals evisceration for atrophia bulbi.

Middle East Afr J Ophthalmol

Department of Ophthalmology, Oculoplastic Unit, Faculty of Medicine, Tanta University, Tanta, Egypt.

Published: August 2015

Purpose: To study the use of four petals evisceration in atrophia bulbi to allow insertion of large orbital implant.

Materials And Methods: An interventional case series. All cases were atrophia bulbi. The axial lengths (AL) of atrophic and contralateral normal eye were measured. It was planned to use implant 3 mm smaller than AL of the contralateral normal eye. Four petals evisceration was used in all cases.

Results: Twenty cases were included. The mean age was 27.08 ± 16.07 years. The mean axial length (AL) of atrophic eyes was 16.97 ± 1.42 mm. In 75% of cases, the planned implant was inserted. In all cases, the implant diameter was larger than AL of atrophic eye by a mean of 2.57 ± 0.64 mm. The AL of atrophic eye did not affect the implant size. The mean follow-up period was 22.4 ± 10.1 months. Implant exposure was not recorded in any case. Volume deficiency was recorded in 2 cases (10%).

Conclusions: Four petals evisceration facilitated the use of suitable sized implant in atrophia bulbi with minimal complications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4411621PMC
http://dx.doi.org/10.4103/0974-9233.150645DOI Listing

Publication Analysis

Top Keywords

petals evisceration
16
atrophia bulbi
16
evisceration atrophia
8
contralateral normal
8
normal eye
8
planned implant
8
atrophic eye
8
implant
6
cases
5
petals
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!