Efficiency assessment of immunochromatographic strip test for the diagnosis of alpha-thalassemia-1 carriers.

J Lab Physicians

Department of Applied Science, Faculty of Science and Technology, Suan Sunandha Rajabhat University, Bangkok 10300, Thailand.

Published: May 2015

Context: The prevention and control of thalassemia in Thailand focus on the appropriate diagnosis with a simple, cheap, and practical tool for any staff to use.

Aims: (1) To screen alpha-thalassemia-1 carriers among pregnant women and spouses by immunochromatographic (IC) strip test and one tube osmotic fragility test (OFT) and (2) to evaluate the accuracy of both screening methods.

Setting And Design: Cross-sectional study for 6 months duration from January to June 2013 at Kudjab Hospital located in Udonthani Province, Thailand.

Subjects And Methods: Pregnant women and spouses attending the antenatal care clinic joined the study for blood sample collection (n = 414). The specimens were then taken for screening by osmotic fragility and IC strip test to specify alpha-thalassemia carriers. Another set of the specimens was sent for testing using hemoglobin (Hb) typing for thalassemia and abnormal Hb carriers and using multiplex polymerase chain reaction for alpha-thalassemia-1 carriers diagnosis as a gold standard.

Results: There were 27 cases found as positive for alpha-thalassemia including alpha-thalassemia-1 carriers, South East Asian type, alpha-thalassemia-1 carriers, Thai deletion type, HbH and Hb constant spring, which were 18, 2, 3, and 2 cases, respectively. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of IC strip test were 92.6%, 95.1%, 56.8%, 99.4%, and 94.9%, respectively, which were higher than those of OFT.

Conclusions: Accuracy of IC strip test was better than those of OFT. IC strip test may probably be very helpful in a massive thalassemia screening program.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4411809PMC
http://dx.doi.org/10.4103/0974-2727.154779DOI Listing

Publication Analysis

Top Keywords

strip test
24
alpha-thalassemia-1 carriers
20
immunochromatographic strip
8
pregnant women
8
women spouses
8
osmotic fragility
8
accuracy strip
8
test
7
carriers
7
strip
6

Similar Publications

A novel Schirmer Strip-Based Tear Matrix Metalloproteinase Measurement in Dry Eye Evaluation.

Ocul Surf

January 2025

Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences; Key Laboratory of Ocular Fundus Diseases, Chinese Academy of Medical Sciences. Electronic address:

Unlabelled: Dry eye disease is a multifactorial disorder of the ocular surface with increasing global prevalence, yet no universally accepted "gold standard" exists for its diagnosis or severity assessment. Tear matrix metalloproteinase 9 (MMP-9) is widely recognized as a valuable biomarker for dry eye, yet there remains a critical need for a simple, accurate, and broadly applicable method for its quantification. This study aims to develop and evaluate a Schirmer strip-based Eu-time resolved fluorescence immunochromatography (Eu-TRFICO) method for the quantitative detection of MMP-9 in tears.

View Article and Find Full Text PDF

Purpose: To compare the color alteration, surface roughness and microhardness and cross-sectional microhardness of bovine enamel treated with at-home whitening strips and gels.

Materials And Methods: Sixty-six pigmented specimens (n = 11) were allocated to six groups: C-cotton wool moistened with distilled water for 1 h; SDS-sodium dithionite strip, for 1 h; HPS-6.5% hydrogen peroxide strip, for 1 h; CPS-20% carbamide peroxide strip, for 1 h; HPG-7.

View Article and Find Full Text PDF

Lab-on-paper for molecular testing with USB-powered isothermal amplification and fluidic control.

Mikrochim Acta

January 2025

Department of Biotechnology and Bioengineering, Chonnam National University, Gwangju, 61186, Republic of Korea.

The global healthcare market increasingly demands affordable molecular diagnostics for field testing. To address this need, we introduce a lab-on-paper (LOP) platform that integrates isothermal amplification with a specially designed paper strip for molecular testing through an automated microfluidics process. The LOP system is engineered for rapid, cost-effective, and highly sensitive detection, using USB-powered thermal management and a wax valve mechanism.

View Article and Find Full Text PDF

Current American Urological Association guidelines recommend that patients with acute obstructive kidney stone requiring continuous anticoagulation/antiplatelet therapy should not be treated by shockwave lithotripsy or percutaneous nephrolithotomy because of the risk of catastrophic renal hemorrhage possible with those techniques. Currently, ureteroscopy is the only recommended surgical treatment. We evaluated if burst wave lithotripsy (BWL) could be used in these cases by treating pigs with BWL while undergoing anticoagulation therapy.

View Article and Find Full Text PDF

Reliability of various Antimicrobial Susceptibility Testing Methods for Piperacillin/tazobactam in challenging Escherichia coli isolates.

J Glob Antimicrob Resist

January 2025

Department of Medical Microbiology and Infectious Diseases, Erasmus University Medical Center, Rotterdam, The Netherlands. Electronic address:

Piperacillin/tazobactam antimicrobial susceptibility testing (AST) against Enterobacterales can be challenging. The aim of this study was to assess the reproducibility of various automated (Vitek®2) and non-automated AST methods (broth microdilution (BMD), minimum inhibitory concentration (MIC) test strip, and disk diffusion) for piperacillin/tazobactam in 'challenging' E. coli isolates.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!