Background: Wear debris of polyethylene has become a restraining factor of the durability for total hip arthroplasty (THA). Ceramic on ceramic (COC) has better wear resistance while the squeaking sound and prosthesis fracture are of concern. It is still a controversy that bearing couples are better for THA.

Methods: We performed a systematic review of all English articles identified from PubMed (1966-), Embase (1980-) and the Cochrane Library. Clinical outcomes, complications, revision rates, and radiographic outcomes of COC-THA and ceramic on polyethylene (COP)-THA were compared and evaluated.

Results: Eight prospective randomized trials enrolling a total of 1508 patients and 1702 THA surgeries were identified. Our results demonstrated the prosthesis fracture and the squeaking sound is significantly higher in COC group and higher wear rate of the COP. Hip function, loosening rate, dislocation rate, revision rate, and the osteolysis rate were comparable between two groups. According to Grading of Recommendations Assessment, Development and Evaluation system assessment, the strength of evidence was high for prosthesis fracture, dislocation, osteolysis, and moderate for radiolucent line or loosening, hip noise, and revision.

Conclusions: Up to now, there is insufficient evidence to identify any clinical advantage of COC compared with COP. Longer follow-up of larger randomized trial is needed to clarify the outcomes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4831551PMC
http://dx.doi.org/10.4103/0366-6999.156136DOI Listing

Publication Analysis

Top Keywords

prosthesis fracture
12
ceramic ceramic
8
total hip
8
hip arthroplasty
8
prospective randomized
8
squeaking sound
8
rate
5
ceramic
4
ceramic ceramic-on-polyethylene
4
ceramic-on-polyethylene total
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!