Purpose: To compare the abilities of retinal nerve fiber layer (RNFL) parameters of variable corneal compensation (VCC) and enhanced corneal compensation (ECC) algorithms of scanning laser polarimetry (GDx) in detecting various severities of glaucoma.

Methods: Two hundred and eighty-five eyes of 194 subjects from the Longitudinal Glaucoma Evaluation Study who underwent GDx VCC and ECC imaging were evaluated. Abilities of RNFL parameters of GDx VCC and ECC to diagnose glaucoma were compared using area under receiver operating characteristic curves (AUC), sensitivities at fixed specificities, and likelihood ratios.

Results: After excluding 5 eyes that failed to satisfy manufacturer-recommended quality parameters with ECC and 68 with VCC, 56 eyes of 41 normal subjects and 161 eyes of 121 glaucoma patients [36 eyes with preperimetric glaucoma, 52 eyes with early (MD>-6 dB), 34 with moderate (MD between -6 and -12 dB), and 39 with severe glaucoma (MD<-12 dB)] were included for the analysis. Inferior RNFL, average RNFL, and nerve fiber indicator parameters showed the best AUCs and sensitivities both with GDx VCC and ECC in diagnosing all severities of glaucoma. AUCs and sensitivities of all RNFL parameters were comparable between the VCC and ECC algorithms (P>0.20 for all comparisons). Likelihood ratios associated with the diagnostic categorization of RNFL parameters were comparable between the VCC and ECC algorithms.

Conclusion: In scans satisfying the manufacturer-recommended quality parameters, which were significantly greater with ECC than VCC algorithm, diagnostic abilities of GDx ECC and VCC in glaucoma were similar.

Download full-text PDF

Source
http://dx.doi.org/10.1097/IJG.0000000000000267DOI Listing

Publication Analysis

Top Keywords

corneal compensation
12
rnfl parameters
12
vcc ecc
12
ecc vcc
12
diagnostic abilities
8
enhanced corneal
8
gdx vcc
8
manufacturer-recommended quality
8
quality parameters
8
glaucoma
7

Similar Publications

Purpose: to determine the effect of lower eyelid blepharoplasty (LEB) surgery on corneal biomechanical parameters before and four months after the procedure. Method: In this prospective longitudinal study, corneal biomechanical parameters measured by Corneal Visualization Scheimpflug Technology (Corvis ST, CVS, Oculus Optikgeräte GmbH, Germany) device were evaluated before and four months after LEB surgery.

Results: The study included 19 eyelids of the right eyes of 19 patients who underwent LEB, with a mean age of 49.

View Article and Find Full Text PDF

Assessment of measurement variability across automated biometry devices.

J Cataract Refract Surg

November 2024

Sengi, Penniac, NB Canada E3A 8X8.

Purpose: To evaluate measurement variability between different readily available automated biometric devices for the purposes of improving surgeon decision making for phakic intraocular lens (IOL) sizing.

Setting: Private practice (Houston, TX, USA).

Design: Prospective, single center, bilateral, non-randomized, open-label, observational study.

View Article and Find Full Text PDF

Visual Quality Following Femtosecond Laser-Assisted In Situ Keratomileusis With Q-Value-Guided Optimized Monovision in Patients With Myopia and Presbyopia.

Am J Ophthalmol

November 2024

From the Department of Ophthalmology, Peking University Third Hospital (R.Z., Y.Y., Y.Z., Y.C.), Beijing, China; Beijing key laboratory of restoration of damaged ocular nerve, Peking University Institute of Laser Medicine (R.Z., Y.Y., Y.Z., Y.C.), Beijing, China. Electronic address:

Purpose: To evaluate the objective and subjective visual quality 3 months after femtosecond laser-assisted in situ keratomileusis (FS-LASIK) performed with Q-value-guided optimized monovision scheme (Custom-Q) for correction of myopia with or without astigmatism and compensate for age-related accommodation deficiency.

Design: Prospective before-and-after study.

Methods: Patients who had Custom-Q FS-LASIK for myopia with age-related accommodation deficiency were included in this prospective study.

View Article and Find Full Text PDF

We investigated how long-term visual experience with habitual spherical aberration (SA) influences subjective depth of focus (DoF). Nine healthy cycloplegic eyes with habitual SAs of different signs and magnitudes were enrolled. An adaptive optics (AO) visual simulator was used to measure through-focus high-contrast visual acuity after correcting all monochromatic aberrations and imposing + 0.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to investigate corneal stiffening after epithelium-off accelerated corneal cross-linking (CXL; 9 mW/cm²) in progressive keratoconus (KC) with different methods of epithelial debridement.

Methods: This was a retrospective, interventional, and non-randomized study. In group 1, the epithelium was removed using a hockey knife (N = 45).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!