In vivo bone formation by human alveolar-bone-derived mesenchymal stem cells obtained during implant osteotomy using biphasic calcium phosphate ceramics or Bio-Oss as carriers.

J Biomed Mater Res B Appl Biomater

Department of Periodontology, Research Institute for Periodontal Regeneration, College of Dentistry, Yonsei University, Seoul, Republic of Korea.

Published: April 2016

Objectives: The aim of this study was to evaluate HA coated with different ratios of TCP as a carrier for hABMSCs obtained during implant osteotomy in comparison to slowly-resorbing biomaterial, Bio-Oss, as a negative control, using in vitro and in vivo experiments.

Materials And Methods: Human ABMSCs (hABMSCs) harvested during implant osteotomy were transplanted using HA/TCP or Bio-Oss as carriers in a murine ectopic transplantation model (n = 12). Pore size and cell affinity were evaluated in vitro. The area of newly formed bone was analyzed histometrically, the number of osteocytes was counted, and immunohistochemical staining was conducted against several markers of osteogenesis, including alkaline phosphatase (ALP), runt-related transcription factor 2 (RUNX-2), osteocalcin (OCN), and osteopontin (OPN). Osteoclast formation was evaluated by tartrate-resistant acid phosphatase staining.

Results: The carrier materials had comparable pore sizes. The cell affinity assay resulted in a high proportion of cell adhesion (>90%) in all experimental groups. Substantial new bone and osteocyte formation was observed on both HA/TCP carriers, whereas it was minimal with Bio-Oss. Positive immunostaining for ALP, RUNX-2, OCN, and OPN was observed with HA/TCP, but only limited expression of osteogenic markers with Bio-Oss. Conversely, there was a minimal osteoclast presence with Bio-Oss, but a significant presence of osteoclasts with both HA/TCP carriers.

Conclusions: Both types of scaffolds, BCP and Bio-Oss, showed high stem cell-carrying potential, but the in vivo healing patterns of their complexes with hABMSC could be affected by the microenvironment on the surfaces of the scaffolds.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jbm.b.33416DOI Listing

Publication Analysis

Top Keywords

implant osteotomy
12
bio-oss carriers
8
cell affinity
8
observed ha/tcp
8
bio-oss
7
vivo bone
4
bone formation
4
formation human
4
human alveolar-bone-derived
4
alveolar-bone-derived mesenchymal
4

Similar Publications

Purpose: Olecranon osteotomy has been associated with loss of reduction, nonunion, implant failure, and migration of wires. We aim to evaluate quality of reduction of the osteotomy site as a predictor of olecranon osteotomy nonunion.

Methods: One hundred and twenty-five distal humerus fractures that underwent open reduction internal fixation (ORIF) were reviewed.

View Article and Find Full Text PDF

Radiostereometric Analysis (RSA) is the most accurate method for determining early micromotions of orthopedic implants. Computed Tomography Radiostereometric Analysis (CT-RSA) is a method that can be used to determine implant and bone micromovements using low-dose CT scans. This study aimed to evaluate the reliability of the CT-RSA method in measuring the interfragmental mobility in patients who have undergone a correction osteotomy due to a malunited distal radius fracture.

View Article and Find Full Text PDF

Objective: The objective of this study was to compare a multiple pelvic screw fixation strategy (dual bilateral 4 pelvic screw fixation [4PvS]) with the use of single bilateral 2 pelvic screw fixation (2PvS), with the aim of addressing lumbosacral junction stability.

Methods: This analysis is a single-center, retrospective review of ASD patients treated between 2015 and 2021. All patients had a minimum 2-year follow-up and spinal fusion to the sacrum without sacroiliac fusion and met at least one radiographic and procedural criterion: pelvic incidence-lumbar lordosis ≥ 20°, T1 pelvic angle ≥ 20°, sagittal vertical axis ≥ 7.

View Article and Find Full Text PDF

Patient-specific implant placement in the case of pelvic tumour resection is usually a complex procedure, where the planned optimal position of the prosthesis may differ from the final location. This discrepancy arises from incorrect or differently executed bone resection and improper final positioning of the prosthesis. In order to overcome such mismatch, a navigation solution is presented based on an augmented reality application for HoloLens 2 to assist the entire procedure.

View Article and Find Full Text PDF

Objective: To explore weight-bearing stability of Pilon fracture fixed by external fixator.

Methods: Six ankle bone models (right side) and 4 pairs (8 ankle cadaver specimens) were selected. Pilon fracture model was prepared by using the preset osteotomy line based on Ruedi Allgower Pilon fracture type.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!