Repeatability and Reproducibility of Corneal Biometric Measurements Using the Visante Omni and a Rabbit Experimental Model of Post-Surgical Corneal Ectasia.

Transl Vis Sci Technol

Singapore Eye Research Institute, Singapore ; Singapore National Eye Centre, Singapore ; Department of Clinical Sciences, Duke-NUS Graduate Medical School, Singapore ; School of Material Science & Engineering and School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore.

Published: April 2015

Purpose: To investigate the repeatability and reproducibility of the Visante Omni topography in obtaining topography measurements of rabbit corneas and to develop a post-surgical model of corneal ectasia.

Methods: Eight rabbits were used to study the repeatability and reproducibility by assessing the intra- and interobserver bias and limits of agreement. Another nine rabbits underwent different diopters (D) of laser in situ keratosmileusis (LASIK) were used for the development of ectasia model. All eyes were examined with the Visante Omni, and corneal ultrastructure were evaluated with transmission electron microscopy (TEM).

Results: There was no significant intra- or interobserver difference for mean steep and flat keratometry (K) values of simulated K, anterior, and posterior elevation measurements. Eyes underwent -5 D LASIK had a significant increase in mean amplitude of astigmatism and posterior surface elevation with time ( for trend < 0.05). At 2 and 3 months, the -5 D LASIK group had significant greater mean amplitude of astigmatism ( = 0.036; = 0.027) and posterior surface elevation (both < 0.005) compared with control group. On TEM, the mean collagen fibril diameter and interfibril distance in the -5 D LASIK eyes were significantly greater than in controls at 3 months ( = 0.018; < 0.001).

Conclusions: The Visante Omni provided imaging of the rabbit cornea with good repeatability and reproducibility. Application of -5 D LASIK treatment produced a rabbit model of corneal ectasia that was gradual in development and simulated the human condition.

Translational Relevance: The results provide the foundations for the future evaluation of novel treatment modalities for post-surgical ectasia and keratoconus.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4413927PMC
http://dx.doi.org/10.1167/tvst.4.2.16DOI Listing

Publication Analysis

Top Keywords

repeatability reproducibility
16
visante omni
16
corneal ectasia
8
model corneal
8
intra- interobserver
8
amplitude astigmatism
8
posterior surface
8
surface elevation
8
corneal
5
lasik
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?