Purpose: To estimate the screening test value of routine radiography after arch bar wire removal by assessing the incidence of retained wires and the importance of their sequelae.
Materials And Methods: This was a retrospective medical record review. Records of arch bar removal procedures were examined and divided into those screened with radiography after removal (screen group) and those that were not screened (comparison group). The incidence of retained wire was calculated for each group. Study variables included wire-related radiographic or clinical findings.
Results: Records of 546 mandible fractures were reviewed; 95 met the study criteria. Most exclusions were due to lack of arch bars, missing postoperative radiographs, or insufficient postoperative documentation. Of the 55 records in the screen group, 1 wire was detected (2%); of the 40 records in the comparison group, 1 wire was detected (3%). The total incidence of retained wire findings was not statistically different between the 2 groups and there were no adverse wire-related sequelae reported by any of the 95 patients.
Conclusion: Because of the low incidence of retained wires and wire-related sequelae, routine imaging after wire removal is probably not an effective screening test for retained wire and should be limited to situations in which there is clinical suspicion of retained wire.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.joms.2015.03.070 | DOI Listing |
Heliyon
January 2025
Institute of Sustainable Energy Resources, Universiti Teknologi PETRONAS, Bandar Seri Iskandar, Perak, 32610, Malaysia.
Understanding the behavior of sand screens is crucial for optimizing sand control strategies and preventing wellbore failure, which can significantly impact reservoir management and production efficiency. This paper presents a comprehensive experimental and numerical modeling study on sand screen performance, aimed at providing insights prior to real-field applications. The study evaluated a 200-μm wire-wrapped screen (WWS) using slurry tests to determine the amount of sand retained, sand produced and retained permeability to assess screen efficiency.
View Article and Find Full Text PDFJ Endod
December 2024
Department of Preventive and Restorative Dentistry, University of Sharjah, College of Dental Medicine, Sharjah, UAE.
This report highlights successful management of a rare case of a mandibular premolar with Oehler's Type IIIb Dens Invaginatus (DI) and peri-invagination periodontitis with guided intentional replantation without root canal treatment. A 22-year-old female patient reported with discomfort and a sinus tract associated with tooth number 21. Clinical examination and cone beam computed tomography revealed tooth number 21 had an Oehler's Type IIIb DI with peri-invagination periodontitis.
View Article and Find Full Text PDFCatheter Cardiovasc Interv
January 2025
Interventional Center of Valvular Heart Disease, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
Transcatheter aortic valve replacement (TAVR) procedure was planned for a 68-year-old female patient diagnosed with severe aortic stenosis by transthoracic echocardiography. The first valve unexpectedly dislodged during catheter tip withdrawal after full deployment. A second valve deployment became necessary, posing challenges due to the difficulty of passing the second valve delivery system through the first valve frame.
View Article and Find Full Text PDFCatheter Cardiovasc Interv
January 2025
Oxford Heart Centre, Oxford University Hospitals NHS Trust, Oxford, UK.
Surg Laparosc Endosc Percutan Tech
November 2024
Veterans Affairs Medical Center, White River Junction, VT.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!