Objective: We sought to evaluate a recently proposed protocol whereby transabdominal ultrasound of the cervix might be used as a prescreen to select women to undergo or to forgo measurement of cervical length via transvaginal ultrasound (CLvag).

Study Design: This was a prospective cohort study. Measurements of cervical length via transabdominal ultrasound (CLabd) and CLvag were made in women with singleton pregnancy during routine obstetrical ultrasound examination at 18(0/7) to 23(6/7) weeks of gestation. The transabdominal screen was considered positive if CLabd was ≤36 mm with the maternal bladder full or ≤35 mm with the bladder empty, or adequate imaging of the cervix could not be obtained. Sensitivity, specificity, predictive values, and likelihood ratios of a positive screen to detect a short cervix (CLvag ≤25 mm) were calculated.

Results: An interim analysis identified several technical problems with CLabd measurements, so the protocol was extensively revised. Under the revised protocol, 1580 women were included. Adequate views of the cervix were obtained via transabdominal imaging in 46% of subjects with the bladder empty and 56% with the bladder full. The correlation between CLabd and CLvag was poor (r = 0.38). Of the 17 patients with a short cervix, 15 had suboptimal transabdominal exams (screen positive) and 2 had CLabd ≤35 mm with bladder empty (screen positive). Sensitivity of the screen was 100% (95% confidence interval, 80.5-100%) but specificity was only 32.2% (95% confidence interval, 29.9-34.6%) and screen positive rate was 66.3%. Several technical problems and limitations of transabdominal imaging of the cervix are shown.

Conclusion: Using modern, high-resolution ultrasound equipment, we were unable to adequately image the cervix via transabdominal ultrasound in half the cases. Although we confirmed that a CLabd cutoff value of 35-36 mm is appropriate for detection of short cervix, the technique for measuring CLabd is fraught with technical problems. Practitioners must validate the technique in their own practice before adopting this or similar prescreening protocols. We decided not to adopt this protocol.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ajog.2015.04.022DOI Listing

Publication Analysis

Top Keywords

transabdominal ultrasound
16
short cervix
16
bladder empty
12
technical problems
12
screen positive
12
cervix
9
transabdominal
8
protocol transabdominal
8
cervical length
8
clabd clvag
8

Similar Publications

Heterotopic pregnancy is defined as the concurrent presence of both an intrauterine pregnancy and an extrauterine (typically ectopic) pregnancy. This report presents the case of a 36-year-old female patient who presented to the emergency department with lower abdominal pain. A comprehensive evaluation, including transabdominal and transvaginal ultrasound imaging, revealed a heterotopic pregnancy at an estimated gestational age of six weeks and two days.

View Article and Find Full Text PDF

Ultrasonography in the diagnosis of pelvic vein insufficiency, a systematic review and meta-analysis.

Phlebology

January 2025

Division of Vascular Surgery - 2nd Department of Surgery, "G. Gennimatas" Hospital, Faculty of Medicine, School of Health Sciences, Aristotle University of Thessaloniki, Thessaloniki, Greece.

Objective: To perform a systematic review and meta-analysis to investigate the efficacy of ultrasonography in the diagnosis of pelvic vein insufficiency (PVI).

Results: Seven studies comprised of 802 patients were included. Of these studies, 5 utilised transvaginal ultrasound (TVU), 1 utilised transabdominal ultrasound (TAU) and 1 utilised both ultrasounds as diagnostic tool .

View Article and Find Full Text PDF

Abnormal uterine bleeding (AUB) is a common gynecological condition that disrupts women's health due to irregularities in menstrual frequency, duration, and volume, often resulting in a significant impact on daily life and productivity. Accurate diagnosis of AUB is critical but complicated by its varied etiologies and presentations. Recent advancements in imaging techniques, particularly the Morphological Uterus Sonographic Assessment (MUSA), have enhanced the diagnostic precision of uterine pathologies such as fibroids and adenomyosis.

View Article and Find Full Text PDF

Purpose: To assess the effects of bladder fullness and lower uterine contractions ultrasound on transabdominal and transvaginal cervical length measurements at the mid-trimester fetal anomaly scan (FAS).

Methods: Transabdominal and transvaginal cervical length measurements from 925 mid-trimester FAS examinations were retrospectively analysed. Images were assessed for lower uterine contraction and bladder fullness using a novel qualitative assessment.

View Article and Find Full Text PDF

Ultrasound characteristics and risk factors of female patients with pelvic varicose veins and concomitant chronic pelvic pain.

J Vasc Surg Venous Lymphat Disord

December 2024

Beijing Shijitan Hospital, No.10 Tieyi Road, Haidian District, Beijing, China, 100038. Electronic address:

Objective: The study aims to elucidate clinical and ultrasonographic characteristics of female patients diagnosed with pelvic varicose veins (PVV) and to assess potential risk factors associated with incidences of chronic pelvic pain (CPP) in this population.

Methods: Clinical and ultrasound data were retrospectively collected from female patients with PVV at Beijing Shijitan Hospital between December 2017 and October 2022. Patient cohorts were divided into two groups based on whether they had been experiencing non-periodic pelvic pain over six months, consistent with the symptoms of CPP.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!