A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

HPLC-MS-MS Method Development and Validation of Antileishmanial Agent, S010-0269, in Hamster Serum. | LitMetric

HPLC-MS-MS Method Development and Validation of Antileishmanial Agent, S010-0269, in Hamster Serum.

J Chromatogr Sci

Pharmacokinetics & Metabolism Division, CSIR-Central Drug Research Institute, Jankipuram Extension, Sitapur Road, Lucknow 226 031, India Academy of Scientific and Innovative Research, New Delhi, India

Published: October 2015

A rapid, sensitive and simple high-performance liquid chromatography-tandem mass spectrometry method was developed and validated for the quantification of the antileishmanial agent, S010-0269, in hamster serum. A Discovery HS C-18 column (5 μm, 50 × 4.6 mm) maintained at 40°C was utilized for chromatographic separation with mobile phase [acetonitrile: aqueous ammonium acetate (0.01 M) buffer (85:15, v/v)] at a flow rate of 0.6 mL/min. The method requires low serum volume (20 µL) with a run time of 3.5 min. Excellent linear relationships (r ≥ 0.99) were obtained between the measured and added concentration over a range of 1-200 ng/mL. Validation parameters (accuracy, specificity, precision, recovery, matrix effect and stability) were assessed as per FDA guidelines. The precision and accuracy were acceptable as indicated by relative standard deviation ranging from 2.3 to 13.6% and bias values ranging from 1.5 to 6.5%, respectively. Moreover, the compound was found stable in hamster serum even after 30 days of storage at -80°C and being subjected to two freeze-thaw cycles. The validated method was successfully applied to the pharmacokinetic study after 10 mg/kg oral dose of S010-0269 in hamsters.

Download full-text PDF

Source
http://dx.doi.org/10.1093/chromsci/bmv050DOI Listing

Publication Analysis

Top Keywords

hamster serum
12
antileishmanial agent
8
agent s010-0269
8
s010-0269 hamster
8
hplc-ms-ms method
4
method development
4
development validation
4
validation antileishmanial
4
serum
4
serum rapid
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!