Electroencephalogram (EEG) plays an important role in E-healthcare systems, especially in the mental healthcare area, where constant and unobtrusive monitoring is desirable. In the context of OPTIMI project, a novel, low cost, and light weight wearable EEG sensor has been designed and produced. In order to improve the performance and reliability of EEG sensors in real-life settings, we propose a method to evaluate the quality of EEG signals, based on which users can easily adjust the connection between electrodes and their skin. Our method helps to filter invalid EEG data from personal trials in both domestic and office settings. We then apply an algorithm based on Discrete Wavelet Transformation (DWT) and Adaptive Noise Cancellation (ANC) which has been designed to remove ocular artifacts (OA) from the EEG signal. DWT is applied to obtain a reconstructed OA signal as a reference while ANC, based on recursive least squares, is used to remove the OA from the original EEG data. The newly produced sensors were tested and deployed within the OPTIMI framework for chronic stress detection. EEG nonlinear dynamics features and frontal asymmetry of theta, alpha, and beta bands have been selected as biological indicators for chronic stress, showing relative greater right anterior EEG data activity in stressful individuals. Evaluation results demonstrate that our EEG sensor and data processing algorithms have successfully addressed the requirements and challenges of a portable system for patient monitoring, as envisioned by the EU OPTIMI project.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TNB.2015.2420576DOI Listing

Publication Analysis

Top Keywords

eeg sensor
12
eeg data
12
eeg
11
wearable eeg
8
optimi project
8
chronic stress
8
signal quality
4
quality assessment
4
assessment model
4
model wearable
4

Similar Publications

Introduction: In recent years, with advancements in wearable devices and biosignal analysis technologies, sports performance analysis has become an increasingly popular research field, particularly due to the growing demand for real-time monitoring of athletes' conditions in sports training and competitive events. Traditional methods of sports performance analysis typically rely on video data or sensor data for motion recognition. However, unimodal data often fails to fully capture the neural state of athletes, leading to limitations in accuracy and real-time performance when dealing with complex movement patterns.

View Article and Find Full Text PDF

Study Objectives: Polysomnography (PSG) currently serves as the benchmark for evaluating sleep disorders. Its discomfort makes long-term monitoring unfeasible, leading to bias in sleep quality assessment. Hence, less invasive, cost-effective, and portable alternatives need to be explored.

View Article and Find Full Text PDF

ESI-GAL: EEG source imaging-based trajectory estimation for grasp and lift task.

Comput Biol Med

December 2024

Department of Electrical Engineering, Indian Institute of Technology Delhi, New Delhi 110016, India; Bharti School of Telecommunication, Indian Institute of Technology Delhi, New Delhi 110016, India; Yardi School of Artificial Intelligence, Indian Institute of Technology Delhi, New Delhi 110016, India. Electronic address:

Background: Electroencephalogram (EEG) signals-based motor kinematics prediction (MKP) has been an active area of research to develop Brain-computer interface (BCI) systems such as exosuits, prostheses, and rehabilitation devices. However, EEG source imaging (ESI) based kinematics prediction is sparsely explored in the literature.

Method: In this study, pre-movement EEG features are utilized to predict three-dimensional (3D) hand kinematics for the grasp-and-lift motor task.

View Article and Find Full Text PDF

Recently, social demands for a good quality of life have increased among the elderly and disabled people. So, biomedical engineers and robotic researchers aimed to fuse these techniques in a novel rehabilitation system. Moreover, these models utilized the biomedical signals acquired from the human body's particular organ, cells, or tissues.

View Article and Find Full Text PDF

Objective: Electroencephalography (EEG) and Magnetoencephalography (MEG) are widely used non-invasive techniques in clinical and cognitive neuroscience. However, low spatial resolution measurements, partial brain coverage by some sensor arrays, as well as noisy sensors could result in distorted sensor topographies resulting in inaccurate reconstructions of underlying brain dynamics. Solving these problems has been a challenging task, This paper proposes a robust framework based on electromagnetic source imaging for interpolation of unknown or poor quality EEG/MEG measurements.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!