A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluating the reliability of a novel neck-strength assessment protocol for healthy adults using self-generated resistance with a hand-held dynamometer. | LitMetric

Purpose: To evaluate the intra- and inter-session test-retest agreement of a novel neck-strength assessment protocol using a hand-held dynamometer.

Background: A literature review found a lack of neck-strength assessment protocols that are both portable and reliable. Hand-held dynamometry is a portable and inexpensive method of assessing muscle strength, but it is not commonly used for neck-strength assessment.

Methods: A hand-held dynamometer was used to evaluate neck strength in 30 healthy participants. The device measured maximum force in cervical flexion, extension, side flexion, side flexion with rotation, and pure rotation, using the ipsilateral hand to apply isometric resistance over 3 seconds. Three measurements were taken over 6-8 days.

Results: Test-retest intra-class correlation coefficients (ICCs) showed high reliability, ranging from 0.94 to 0.97 for all tested directions from Trial 1 to Trial 2 (intra-session reliability, ICC [2,1], absolute). ICC values demonstrated good to high inter-session reliability, ranging from 0.87 to 0.95 for all tested directions from Trial 1 to Trial 3 (ICC [2,1], absolute).

Conclusion: The results suggest that the five test positions of the neck and upper-quadrant strength assessment protocol can be performed using hand-held dynamometry with good to high reliability.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4403327PMC
http://dx.doi.org/10.3138/ptc.2013-66DOI Listing

Publication Analysis

Top Keywords

neck-strength assessment
12
assessment protocol
12
novel neck-strength
8
hand-held dynamometer
8
hand-held dynamometry
8
side flexion
8
high reliability
8
reliability ranging
8
tested directions
8
directions trial
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!