Unlabelled: Before (166)Ho radioembolization, a small batch of the same type of microspheres is administered as a scout dose instead of the conventional (99m)Tc-macroaggregated albumin ((99m)Tc-MAA). The (166)Ho scout dose provides a more accurate and precise lung shunt assessment. However, in contrast to (99m)Tc-MAA, an unintended extrahepatic deposition of this β-emitting scout dose could inflict radiation damage, the extent of which we aimed to quantify in this study.

Methods: All patients eligible for radioembolization in our institute between January 2011 and March 2014 were reviewed. Of the extrahepatic depositions of (99m)Tc-MAA on SPECT, the amount and volume were measured. These were used to calculate the theoretic absorbed dose in the case a (166)Ho scout dose had been used. The extrahepatic activity was measured as the sum of all voxels of the deposition. Volumes were measured using a threshold technique including all voxels from the maximum voxel intensity up to a certain percentage. The threshold needed to obtain the true volume was studied in a phantom study.

Results: In the phantom study, a threshold of 40% was found to overestimate the volume, with the consequence of underestimating the absorbed dose. Of 160 patients, 32 patients (34 cases) of extrahepatic deposition were identified. The depositions contained a median of 1.3% (range, 0.1%-19.5%) of the administered activity in a median volume of 6.8 mL (range, 1.1-42 mL). The use of a scout dose of 250 MBq of (166)Ho microspheres in these cases would theoretically have resulted in a median absorbed dose of 6.0 Gy (range, 0.9-374 Gy). The dose exceeded a limit of 49 Gy (reported in 2013) in 2 of 34 cases (5.9%; 95% confidence interval, 0.7%-20.1%) or 2 of 160 (1.3%; 95% confidence interval, 0.1%-4.7%) of all patients. In these 2 patients with a large absorbed dose (112 and 374 Gy), the culprit vessel was identified in 1 case.

Conclusion: Extrahepatic deposition of a (166)Ho scout dose seems to be theoretically safe in most patients. Its safety in clinical practice is being evaluated in ongoing clinical trials.

Download full-text PDF

Source
http://dx.doi.org/10.2967/jnumed.115.155564DOI Listing

Publication Analysis

Top Keywords

scout dose
28
absorbed dose
16
dose
12
166ho scout
12
extrahepatic deposition
12
166ho microspheres
8
patients patients
8
95% confidence
8
confidence interval
8
166ho
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!