A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Safety and diagnostic performance of image-guided lung biopsy in the targeted therapy era. | LitMetric

Objective Of The Study: To identify risk factors for the adverse events and determine the diagnostic yield of a large series of image-guided thoracic biopsies performed in a single institution.

Materials And Methods: We reviewed a consecutive series of 811 patients (546 males; average age: 68 years.) who underwent 824 image-guided biopsies of pulmonary lesions performed between 2009 and 2013. Indications for biopsy were always evaluated by a multidisciplinary board. All complications were registered. The diagnostic accuracy was calculated on the basis of histology after surgery, response to medical therapy, or outcome at imaging follow-up. Safety and accuracy was correlated with patient-related and lesion-related factors.

Results: 61 biopsies were performed under US-guidance, 750 under CT-guidance, and 13 under combined guidance. The average lesion size was 36.4 mm (6-150 mm). FNAB was exclusively performed in 247 patients, whereas 577 patients underwent also or only core biopsy (CB). 40 (4.8 %) major complications and 172 (20.8 %) minor complications occurred. US-guidance, absence of perilesional emphysema and minor depth of the target lesion from the skin resulted as favorable predictors against major complications. According to the gold standard criteria, we demonstrated 497 true positives, 72 true negatives, 18 false negatives, 0 false positives. Sensitivity, specificity and diagnostic accuracy were 96.5, 100 and 97 %. No predictors for accuracy were found, but the number of samples largely related to the pathologist on site.

Conclusions: Image-guided lung biopsy is safe and highly accurate for diagnosing thoracic lesions. In the targeted therapy era, CB with larger needles can be safely applied when the need for larger amounts of tumor tissue is presumed.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11547-015-0538-9DOI Listing

Publication Analysis

Top Keywords

image-guided lung
8
lung biopsy
8
targeted therapy
8
therapy era
8
biopsies performed
8
diagnostic accuracy
8
major complications
8
negatives false
8
safety diagnostic
4
diagnostic performance
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!