The chemical oxygen demand (COD) of substrate can affect the microbial activity of both anode and cathode biofilm in the single-chamber methanogenic microbial electrolysis cell (MEC). In order to investigate the effect of COD on the performance of MEC, a single chamber MEC was constructed with biocathode. With the change of initial concentration of COD (700, 1 000 and 1 350 mg x L(-1)), the methane production rate, COD removal and energy efficiency in the MEC were examined under different applied voltages. The results showed that the methane production rate and COD removal increased with the increasing COD. With the applied voltage changing from 0.3 to 0.7 V, the methane production rate increased at the COD of 700 mg x L(-1), while it increased at first and then decreased at the COD of 1000 mg x L(-1) and 1350 mg x L(-1). A similar trend was observed for the COD removal. The cathode potential reached the minimum (- 0.694 ± 0.001) V as the applied voltage was 0.5 V, which therefore facilitated the growth of methanogenic bacteria and improved the methane production rate and energy efficiency of the MEC. The maximum energy income was 0.44 kJ ± 0.09 kJ (1450 kJ x m(-3)) in the MEC, which was obtained at the initial COD of 1000 mg x L(-1) and the applied voltage of 0.5 V. Methanogenic MECs could be used for the treatment of wastewaters containing low organic concentrations to achieve positive energy production, which might provide a new method to recover energy from low-strength domestic wastewater.