Background: The purpose of this systematic review was to evaluate the safety of dental implants placed in irradiated bone and to discuss their viability when placed post-radiotherapy (RT).

Methods: A systematic review was performed to answer the questions: "Are dental implants in irradiated bone viable?" and "What are the main factors that influence the loss of implants in irradiated patients?"

Results: The search strategy resulted in 8 publications. A total of 331 patients received 1237 implants, with an overall failure rate of 9.53%. The osseointegration success rates ranged between 62.5% and 100%. The optimal time interval between irradiation and dental implantation varied from 6 to 15 months.

Conclusion: The interval time between RT and implant placement and the radiation doses are not associated with significant implant failure rates. The placement of implants in irradiated bone is viable, and head and neck RT should not be considered as a contraindication for dental rehabilitation with implants. © 2015 Wiley Periodicals, Inc. Head Neck 38: E2229-E2240, 2016.

Download full-text PDF

Source
http://dx.doi.org/10.1002/hed.24098DOI Listing

Publication Analysis

Top Keywords

implants irradiated
16
dental implants
12
head neck
12
systematic review
12
irradiated bone
12
implants
7
irradiated
5
viability dental
4
implants head
4
neck irradiated
4

Similar Publications

Multi-Functional Bio-HJzyme Engineered Polyetheretherketone Implant with Cascade-Amplification Therapeutic Capabilities Toward Intractable Implant-Associated Infections.

Small

December 2024

State Key Laboratory of Oral Diseases, School of Chemical Engineering, National Center for Stomatology & National Clinical Research Center for Oral Diseases, Sichuan University, Chengdu, 610041, China.

Intractable implant-associated infections (IAIs) are the primary cause of prosthetic implant failure, particularly in the context of diabetes mellitus. There is an urgent need to design and construct versatile engineered implants integrated with cascade amplification therapeutic modality to significantly improve the treatment of diabetic IAIs. To address this issue, a multi-functional MXene/AgPO@glucose oxidase bio-heterojunction enzyme (M/A@GOx bio-HJzyme) coating is developed, which is decorated with an inert sulfonated polyetheretherketone implant (SP-M/A@G) via hydrothermal treatment and layered deposition.

View Article and Find Full Text PDF

Bacterial implant-associated infections predominantly contribute to the failure of prosthesis implantation. The local biofilm microenvironment (BME), characterized by its hyperacidic condition and high hydrogen peroxide (HO) level, inhibits the host's immune response, thereby facilitating recurrent infections. Here, a Janus PEGylated CuS nanoparticle (CuPen) armed engineered Lactobacillus casei (L.

View Article and Find Full Text PDF

Factors associated with morbidity of a totally implantable venous access device in patients with breast cancer.

Turk J Med Sci

December 2024

Division of General Surgery, Department of Surgery, Institute of Oncology, İstanbul University, İstanbul, Turkiye.

Background/aim: To investigate the possible morbidities associated with the implantation of a totally implantable venous access device (TIVAD) in breast cancer (BC) patients.

Materials And Methods: Clinical data and developed complications in 546 BC patients with TIVAD between 2017 and 2021 were analyzed retrospectively. Among these, 524 (96%) patients who underwent TIVAD implantation via the right subclavian vein (SCV) route were examined separately.

View Article and Find Full Text PDF

Technical Aspects of a National Service for Paediatric Pelvic Brachytherapy.

Clin Oncol (R Coll Radiol)

December 2024

Department of Oncology, University College London Hospitals NHS Foundation Trust, 250 Euston Road, London, NW1 2PG, UK. Electronic address:

Aims: Brachytherapy is advantageous for localised rhabdomyosarcomas in children compared with external beam radiotherapy, sparing close organs at risk with highly conformal dosimetry. A methodology for planning and delivering fractionated high-dose-rate paediatric pelvic brachytherapy is detailed, and the dosimetric parameters are presented. This provides a practical template for radiotherapy departments with a similar patient cohort to implement this treatment technique.

View Article and Find Full Text PDF

A prospectively deployed deep learning-enabled automated quality assurance tool for oncological palliative spine radiation therapy.

Lancet Digit Health

January 2025

Department of Radiation Oncology, Brigham and Women's Hospital, Dana-Farber Cancer Institute, Harvard Medical School, Boston, MA, USA; Artificial Intelligence in Medicine (AIM) Program, Mass General Brigham, Harvard Medical School, Boston, MA, USA. Electronic address:

Background: Palliative spine radiation therapy is prone to treatment at the wrong anatomic level. We developed a fully automated deep learning-based spine-targeting quality assurance system (DL-SpiQA) for detecting treatment at the wrong anatomic level. DL-SpiQA was evaluated based on retrospective testing of spine radiation therapy treatments and prospective clinical deployment.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!