A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Correlation Between Timed Barium Esophagogram and Esophageal Transit Scintigraphy Results in Achalasia. | LitMetric

Correlation Between Timed Barium Esophagogram and Esophageal Transit Scintigraphy Results in Achalasia.

Dig Dis Sci

Department of Internal Medicine, Institute of Gastroenterology, Gangnam Severance Hospital, Yonsei University College of Medicine, 712 Eonjuro, Gangnam-gu, Seoul, 135-720, Korea.

Published: August 2015

Background: Timed barium esophagogram (TBE) and esophageal transit scintigraphy (ETS) have been adopted as useful ways to evaluate achalasia patients. TBE has merit as a simple, non-invasive, and convenient method.

Aims: The study sought to compare the results of these two tests and verify their usefulness in evaluating treatment response. In addition, we assessed whether TBE could effectively replace ETS through correlation analysis.

Methods: The medical records of 50 achalasia patients treated between September 2011 and June 2014 were reviewed retrospectively. The height and width of the barium column at 1, 2, and 5 min were measured by TBE. Half-life (T 1/2, min) and R 30 (percentage of remaining radioactivity 30 s after radioisotope ingestion) were measured by ETS. Both tests were performed before and after treatment, and the tests were carried out 1 and 2 days after procedures. And we analyzed the correlation between the parameters from the two tests.

Results: The parameters of TBE and ETS were improved after treatment (p < 0.05). Before treatment, the height and width results at 5 min from TBE positively correlated with the T 1/2 parameter from ETS (correlation coefficients of 0.59 and 0.75, respectively). After treatment, the correlation coefficients between the 5-min height and width of the barium column by TBE and T 1/2 by ETS were 0.55 and 0.46, respectively.

Conclusions: Both TBE and ETS are useful modalities in assessing esophageal emptying and response to achalasia treatment. TBE and ETS results have a statistically significant correlation both pre- and post-treatment. We suggest that TBE could effectively replace ETS for the assessment of achalasia.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10620-015-3659-zDOI Listing

Publication Analysis

Top Keywords

timed barium
8
barium esophagogram
8
esophageal transit
8
transit scintigraphy
8
achalasia patients
8
tbe
5
correlation timed
4
esophagogram esophageal
4
scintigraphy achalasia
4
achalasia background
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!