A high radiographic inclination angle (RI) contributes to accelerated wear and has been associated with dislocation after total hip arthroplasty (THA). With freehand positioning of the acetabular component there is a lack of accuracy, with a trend towards a high radiographic inclination angle. The aim of this study was to investigate whether the use of a digital protractor to measure the operative inclination angle (OI) could improve the positioning of the acetabular component in relation to a 'safe zone'. We measured the radiographic inclination angles of 200 consecutive uncemented primary THAs. In the first 100 the component was introduced freehand and in the second 100 a digital protractor was used to measure the operative inclination angle. The mean difference between the operative and the radiographic inclination angles (∆RI-OI) in the second cohort was 12.3° (3.8° to 19.8°). There was a strong correlation between the circumference of the hip and ∆RI-OI. The number of RI outliers was significantly reduced in the protractor group (p = 0.002). Adjusting the OI, using a digital protractor and taking into account the circumference of the patient's hip, improves the RI significantly (p < 0.001) and does not require additional operating time.

Download full-text PDF

Source
http://dx.doi.org/10.1302/0301-620X.97B5.34781DOI Listing

Publication Analysis

Top Keywords

digital protractor
16
radiographic inclination
16
inclination angle
16
acetabular component
12
total hip
8
hip arthroplasty
8
circumference hip
8
high radiographic
8
positioning acetabular
8
protractor measure
8

Similar Publications

Article Synopsis
  • Drones are improving nutrient management by allowing precise spraying techniques, which are especially important under climate change.
  • Current research focuses on optimizing various parameters like flight height, pressure, and nozzle configuration to enhance spray efficiency and reduce waste.
  • The study found that a hover height of 2.0 meters provided the best spray uniformity and distribution, showing the effectiveness of careful drone operation in agricultural practices.
View Article and Find Full Text PDF

Purpose: Focusing on individuals with visual impairment, this study investigated the effects of spatial learning using tactile maps on orientation accuracy by path integration in physical and mental imagery walking scenarios.

Materials And Methods: Twelve blindfolded sighted people learned nonlooping routes with two corners using tactile maps composed of volumetric raised-line elements, then navigated the routes physically and mentally. At four orientation points along the route-the starting point, Corner A, Corner B, and the endpoint-participants indicated the direction of the other points by aligning a raised, tapered rectangle attached to a horizontal digital protractor.

View Article and Find Full Text PDF

Aim: To spatially map the position of the facial artery and vein along the inferior border of the mandible based on specific facial reference points.

Methods: This cross-sectional study included 40 sides of 21 formalin-fixed cadaver heads (11 female, 10 male) with a mean age of 72.92 ± 11.

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to create and validate a method for assessing humeral torsion using a single x-ray image, simplifying intraoperative procedures.
  • The Humeral Head Offset Index (HHOI) is calculated by comparing the medial and lateral humeral head offsets, and was tested on models and patient CT images to determine its reliability.
  • Results showed a strong correlation between the HHOI and humeral torsion, indicating the method's effectiveness for clinical application.
View Article and Find Full Text PDF

Background: Various virtual goniometers have been used for photographic measurements. However, there is no single method that is both reliable and valid for measuring the forearm, wrist, and finger joints.

Purpose: This study aimed to investigate the criterion validity and intra- and inter-rater reliability of a virtual goniometer for assessing forearm, wrist, and finger joints using screenshots from video recordings and to calculate the standard error of measurement (SEM) and minimum detectable change (MDC).