A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Colorimetric detection of Bi (III) in water and drug samples using pyridine-2,6-dicarboxylic acid modified silver nanoparticles. | LitMetric

Colorimetric detection of Bi (III) in water and drug samples using pyridine-2,6-dicarboxylic acid modified silver nanoparticles.

Spectrochim Acta A Mol Biomol Spectrosc

Department of Chemistry, Faculty of Science, University of Kurdistan, P.O. Box 416, 66177-15175 Sanandaj, Iran. Electronic address:

Published: September 2015

A new selective, simple, fast and sensitive method is developed for sensing assay of Bi (III) using pyridine-2,6-dicarboxylic acid or dipicolinic acid (DPA) modified silver nanoparticles (DPA-AgNPs). Silver nanoparticles (AgNPs) were synthesized by reducing silver nitrate (AgNO3) with sodium borohydride (NaBH4) in the presence of DPA. Bismuth detection is based on color change of nanoparticle solution from yellow to red that is induced in the presence of Bi (III). Aggregation of DPA-AgNPs has been confirmed with UV-vis absorption spectra and transmission electron microscopy (TEM) images. Under the optimized conditions, a good linear relationship (correlation coefficient r=0.995) is obtained between the absorbance ratio (A525/A390) and the concentration of Bi (III) in the 0.40-8.00 μM range. This colorimetric probe allows Bi (III) to be rapidly quantified with a 0.01 μM limit of detection. The present method successfully applied to determine bismuth in real water and drug samples. Recoveries of water samples were in the range of 91.2-99.6%.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.saa.2015.03.127DOI Listing

Publication Analysis

Top Keywords

silver nanoparticles
12
water drug
8
drug samples
8
pyridine-26-dicarboxylic acid
8
modified silver
8
iii
5
colorimetric detection
4
detection iii
4
iii water
4
samples pyridine-26-dicarboxylic
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!