Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Near infrared spectroscopy (NIRS) allows continuous measurement of cerebral regional oxygen saturation (rSO2). It is a weighted saturation value derived from approximately 70-75 % venous, 20-25 % arterial and 2.5-5 % capillary blood. In contrast to pulse oximetry, NIRS is independent of pulsatile flow. Therefore, it is also applicable during extracorporeal circulation, cardiopulmonary resuscitation (CPR), and hypothermia.
Objectives: The purpose of this work is to describe the application of cerebral and somatic NIRS in cardiology and cardiac surgery patients in the operation room, during and after CPR, and during the intensive care unit stay.
Materials And Methods: This article is based on peer-reviewed literature from PubMed.
Results: Interventions based on decline of cerebral NIRS values during on-pump cardiac surgery can reduce major organ morbidity and mortality; however, the appearance of a postoperative cognitive dysfunction is scarcely influenced. Persisting of low cerebral oximetry values during resuscitation is a marker for not achieving return of spontaneous circulation under normothermia. NIRS is an additional method for monitoring that can be used during extracorporeal circulation.
Conclusion: NIRS is a rapidly available, user-friendly, and noninvasive method for continuous measurement of rSO2. NIRS provides additional information about tissue oxygenation especially during resuscitation and extracorporeal circulatory assist support. Recommendations concerning the use of NIRS for standard monitoring during resuscitation and mechanical circulatory support are not currently available. Further studies are required to show if use of NIRS can reduce pulse control and hands-off times during resuscitation and if use of NIRS can improve outcome after CPR and mechanical circulatory support.