Speckle tracking echocardiography (STE) has been reported to be a promising technique for evaluating right ventricular (RV) function in the clinical setting. On the other hand, the usefulness of STE for RV evaluation in small animal models has not been clarified, although the rat model is among the most commonly used animal models to develop novel effective treatments against pulmonary hypertension and RV heart failure (HF).We validated the use of STE and conventional echocardiographic variables for evaluating RV functions in a rat model by comparing the echocardiographic values of RVHF rats (n = 12) induced by monocrotaline injection with those of control rats (n = 12).Most conventional echocardiographic variables demonstrated that RVHF rats have significant RV dysfunction. The area under the curve (AUC) values to distinguish RV dysfunction in RVHF rats from normal RV function in control rats using fractional area change (FAC), tricuspid annular plane systolic excursion (TAPSE), RV myocardial performance index (MPI), peak tissue Doppler tricuspid annular velocities at systole (Sa), and at early diastole (Ea) were 0.71, 0.98, 0.79, 0.92, and 0.91, respectively. However, using STE analysis for RV evaluation, limited reproducibility was observed (variability 19-37 %, ICC 0.74-0.88) and the only circumferential strain showed significantly lower absolute values (P = 0.039, AUC = 0.76).To evaluate RV function in rat models, circumferential strain may be useful, however, the reproducibility and diagnostic utility were limited. Conventional echocardiographic variables such as TAPSE, tissue Doppler Sa, and Ea have superior diagnostic utility.

Download full-text PDF

Source
http://dx.doi.org/10.1536/ihj.14-367DOI Listing

Publication Analysis

Top Keywords

conventional echocardiographic
12
echocardiographic variables
12
rvhf rats
12
speckle tracking
8
heart failure
8
animal models
8
rat model
8
control rats
8
tricuspid annular
8
tissue doppler
8

Similar Publications

Association with Outcome of the Regurgitant-Volume Adjusted Right Ventricular Ejection Fraction in Secondary Tricuspid Regurgitation.

J Am Soc Echocardiogr

January 2025

Department of Medicine and Surgery, University of Milano-Bicocca, Milan, Italy; Department of Cardiology, Istituto Auxologico Italiano, IRCCS, Milan, Italy.

Background: In patients with secondary tricuspid regurgitation (STR), right ventricular ejection fraction (RVEF) may not accurately reflect the actual RV systolic performance since a considerable amount of the RV stroke volume (SV) is regurgitated back into the right atrium. To overcome this limitation, we explored the association with the outcome of the effective RVEF (eRVEF), which accounts for the tricuspid regurgitant volume (RegVol).

Methods: 513 patients with STR (mean age 75±13 years, 39% atrial STR, 58% severe) underwent complete two-, three-dimensional, and Doppler echocardiography.

View Article and Find Full Text PDF

This study aimed to evaluate the hemodynamic and ventricular performance of neonates with hypoxic-ischemic encephalopathy (HIE) undergoing therapeutic hypothermia using conventional and advanced echocardiographic techniques. This observational, prospective study included 22 neonates with HIE matched with 22 healthy neonates. Echocardiographic studies were performed 24 h after achieving target temperature during hypothermia and 24 h after rewarming.

View Article and Find Full Text PDF

Pulmonary thromboembolism (PTE) is the third most common cause of acute cardiovascular disease, which can lead to high morbidity and mortality if left untreated. Anatomical and electrophysiological variations and obesity may complicate timely diagnosis and delay required management. While computed tomography pulmonary angiography (CTPA) remains the most accurate diagnostic tool, initial assessments using electrocardiography (ECG) or echocardiography can be helpful in early suspicion.

View Article and Find Full Text PDF

Artificial intelligence-enhanced comprehensive assessment of the aortic valve stenosis continuum in echocardiography.

EBioMedicine

January 2025

CONNECT-AI Research Center, Yonsei University College of Medicine, Seoul, Republic of Korea; Ontact Health Inc., Seoul, Republic of Korea; Division of Cardiology, Severance Cardiovascular Hospital, Yonsei University College of Medicine, Yonsei University Health System, Seoul, Republic of Korea.

Background: Transthoracic echocardiography (TTE) is the primary modality for diagnosing aortic stenosis (AS), yet it requires skilled operators and can be resource-intensive. We developed and validated an artificial intelligence (AI)-based system for evaluating AS that is effective in both resource-limited and advanced settings.

Methods: We created a dual-pathway AI system for AS evaluation using a nationwide echocardiographic dataset (developmental dataset, n = 8427): 1) a deep learning (DL)-based AS continuum assessment algorithm using limited 2D TTE videos, and 2) automating conventional AS evaluation.

View Article and Find Full Text PDF

Introduction We aimed to assess whether partial hepatectomy has an influence on conventional and speckle tracking parameters on echocardiography in living liver donors in the early postoperative period. Methods This study was a retrospective study to investigate the cardiac effects of liver donation after the transplant operation in a high-volume liver transplant center. Ninety living liver donors were included in the study.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!