Microdosimetric spread for cell-sized targets exposed to ⁶⁰Co, ¹⁹²Ir and ¹²⁵I sources.

Radiat Prot Dosimetry

Department of Immunology, Genetics and Pathology, Medical Radiation Physics, Uppsala University, Akademiska Sjukhuset, Uppsala SE-75185, Sweden.

Published: September 2015

The magnitude of the spread in specific energy deposition per cell may be a confounding factor in dose-response analysis motivating derivation of explicit data for the most common brachytherapy isotopes (125)I and (192)Ir, and for (60)Co radiation frequently used as reference in RBE studies. The aim of this study is to analyse the microdosimetric spread as given by the frequency distribution of specific energy for a range of doses imparted by (125)I, (192)Ir and (60)Co sources. An upgraded version of the Monte Carlo code PENELOPE was used for scoring energy deposition distributions in liquid water for each of the radiation qualities. Frequency distributions of specific energy were calculated according to the formalism of Kellerer and Chmelevsky. Results indicate that the magnitude of the microdosimetric spread increases with decreasing target size and decreasing energy of the radiation quality. Within the clinical relevant dose range (1 to 100 Gy), the spread does not exceed 4 % for (60)Co, 5 % for (192)Ir and 6 % for (125)I. The frequency distributions can be accurately approximated with symmetrical normal distributions at doses down to 0.2 Gy for (60)Co, 0.1 Gy for (192)Ir and 0.08 Gy for (125)I.

Download full-text PDF

Source
http://dx.doi.org/10.1093/rpd/ncv200DOI Listing

Publication Analysis

Top Keywords

microdosimetric spread
12
specific energy
12
energy deposition
8
125i 192ir
8
192ir 60co
8
frequency distributions
8
60co 192ir
8
energy
5
spread cell-sized
4
cell-sized targets
4

Similar Publications

Variable relative biological effectiveness (RBE) of carbon radiotherapy may be calculated using several models, including the microdosimetric kinetic model (MKM), stochastic MKM (SMKM), repair-misrepair-fixation (RMF) model, and local effect model I (LEM), which have not been thoroughly compared. In this work, we compared how these four models handle carbon beam fragmentation, providing insight into where model differences arise. Monoenergetic and spread-out Bragg peak carbon beams incident on a water phantom were simulated using Monte Carlo.

View Article and Find Full Text PDF

Background: Phenomenological relative biological effectiveness (RBE) models for proton therapy, based on the dose-averaged linear energy transfer (LET), have been developed to address the apparent RBE increase towards the end of the proton range. The results of these phenomenological models substantially differ due to varying empirical assumptions and fitting functions. In contrast, more theory-based approaches are used in carbon ion radiotherapy, such as the microdosimetric kinetic model (MKM).

View Article and Find Full Text PDF

Background And Purpose: Ion beams exhibit an increased relative biological effectiveness (RBE) with respect to photons. This study determined the RBE of oxygen ion beams as a function of linear energy transfer (LET) and dose in the rat spinal cord.

Materials And Methods: The spinal cord of rats was irradiated at four different positions of a 6 cm spread-out Bragg-peak (LET: 26, 66, 98 and 141 keV/µm) using increasing levels of single and split oxygen ion doses.

View Article and Find Full Text PDF

Evaluation of Helium Ion Radiotherapy in Combination with Gemcitabine in Pancreatic Cancer In Vitro.

Cancers (Basel)

April 2024

Heidelberg Ion-Beam Therapy Center (HIT), Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany.

Background: Pancreatic cancer is one of the most aggressive and lethal cancers. New treatment strategies are highly warranted. Particle radiotherapy could offer a way to overcome the radioresistant nature of pancreatic cancer because of its biological and physical characteristics.

View Article and Find Full Text PDF

Background And Purpose: The effort to translate clinical findings across institutions employing different relative biological effectiveness (RBE) models of ion radiotherapy has rapidly grown in recent years. Nevertheless, even for a chosen RBE model, different implementations exist. These approaches might consider or disregard the dose-dependence of the RBE and the radial variation of the radiation quality around the beam axis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!