A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Do split paediatric forearm POP casts need to be completed? A biomechanical study. | LitMetric

Introduction: Displaced paediatric forearm fractures are most often treated by manipulation under anaesthetic, followed by the application of a circumferential Plaster of Paris (POP) splint. Some surgeons choose to split the cast in order to facilitate immediate "spreading" with minimal distress to the patient, should the distal limb become compromised. Usually however, this does not occur, and the cast is completed at a later visit to the plaster room. Time, money and inconvenience could be saved if this modification was not necessary, and the final plaster would be lighter.

Objective: To establish whether the mechanical properties of a split POP are sufficient to stabilise a forearm fracture, and protect the patient from further injury.

Materials And Methods: The repeatability of all tests was established on control samples before undertaking the trial. 42 standardised 8 layer POP cylinders of appropriate dimensions were fabricated, of which 21 were split longitudinally. The splints were subjected to non-destructive tests in 4-point bending (Bending), 3-Point Kinking (kinking) and torsion modes, and the load at clinically relevant end-points was recorded. These simulated the deformity at which the splint no longer provided adequate stability and alignment, or at which the wearer was no longer protected. The splints were then loaded to destruction to establish the mode of ultimate failure.

Results: The mean loads at the clinical end points for split POP splints were: 1375N in Bending, 544N in Kinking and 12 Nm in Torsion (equalling 67.3%, 70.4% and 47.4% of the equivalent values for a circumferential splints). Loads were in excess of body weight for most paediatric patients. After ultimate failure, the proportion of casts that became unstable was similar (44% of full casts and 50% of split casts).

Conclusion: Split POP splints which have not been spread, provide adequate stabilisation and protection of paediatric forearm fractures, and do not routinely require completion.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.injury.2015.04.005DOI Listing

Publication Analysis

Top Keywords

paediatric forearm
12
split pop
12
forearm fractures
8
kinking torsion
8
pop splints
8
split
7
pop
6
splints
5
split paediatric
4
forearm
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!