Bioimpedance spectroscopy for swelling evaluation following total knee arthroplasty: a validation study.

BMC Musculoskelet Disord

CHUV-UNIL, Orthopedics and Traumatology Department, CHUV-UNIL, Avenue du Bugnon 21, 1011, Lausanne, Switzerland.

Published: April 2015

Background: The evaluation of swelling is important for the outcome of total knee arthroplasty (TKA) surgery. The circumference or volume measurements are applicable at the bedside of the patient but are altered by muscular atrophy and the post-surgical dressing. Bioimpedance spectroscopy might overcome these limitations; however, it should be validated. This study aimed to explore the validity, the reliability and the responsiveness of bioimpedance spectroscopy for measuring swelling after TKA.

Methods: The degree of swelling in 25 patients undergoing TKA surgery was measured using bioimpedance spectroscopy (BIS R0), knee circumference and limb volume. The measurements were performed on D-1 (day before surgery), D + 2 (2 days after surgery) and D + 8 (8 days after surgery). The BIS R0 measurements were repeated twice, alternating between two evaluators. The percentage of the difference between the limbs was calculated for BIS R0, circumference and volume. The intra- and inter-observer intraclass correlation coefficients (ICCs), limits of agreement (LOA), effect size (Cohen's d), correlations between the methods and diagnostic sensitivity were calculated.

Results: BIS R0, circumference and volume detected swelling < 3.5% at D-1. The swelling at D2 and D8 was greater with BIS R0 [mean (SD) 29.9% (±9.8) and 38.27 (±7.8)] than with volume [14.7 (±9.5) and 14.9 (±8.2)] and circumference [11.1 (±5.7) and 11.7 (±4.1)]. The BIS R0 intra- and inter-evaluator ICCs ranged from 0.89 to 0.99, whereas the LOA were < 5.2%. The BIS R0 correlation was 0.73 with volume and 0.75 with circumference. The BIS R0 Cohen's d was 3.32 for the D-1-D2 evolution. The diagnostic sensitivity was 83% D2 and 96% at D8.

Conclusion: Bioimpedance is a valid method for the evaluation of swelling following TKA. BIS R0 also demonstrated excellent intra- and inter-evaluator reliability. The diagnostic sensitivity and responsiveness is superior to that of concurrent methods. BIS R0 is an efficient method for post-surgical follow up at the bedside of the patient. The measurement of BIS R0 is a straightforward, valid, reliable and responsive method for lower limb swelling following TKA surgery that could be used in clinics and research.

Trial Registration: ClinicalTrials.gov Identifier: NCT00627770.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4422299PMC
http://dx.doi.org/10.1186/s12891-015-0559-5DOI Listing

Publication Analysis

Top Keywords

bioimpedance spectroscopy
16
circumference volume
12
total knee
8
knee arthroplasty
8
tka surgery
8
volume measurements
8
days surgery
8
bis circumference
8
surgery
5
bioimpedance
4

Similar Publications

Progressive Approaches in Oncological Diagnosis and Surveillance: Real-Time Impedance-Based Techniques and Advanced Algorithms.

Bioelectromagnetics

January 2025

Micropropulsion and Nanotechnology Laboratory, School of Engineering and Applied Science, George Washington University, Washington, DC, USA.

Cancer remains a formidable global health challenge, necessitating the development of innovative diagnostic techniques capable of early detection and differentiation of tumor/cancerous cells from their healthy counterparts. This review focuses on the confluence of advanced computational algorithms with noninvasive, label-free impedance-based biophysical methodologies-techniques that assess biological processes directly without the need for external markers or dyes. This review elucidates a diverse array of state-of-the-art impedance-based technologies, illuminating distinct electrical signatures inherent to cancer vs healthy tissues.

View Article and Find Full Text PDF

To reduce hip joint muscles' activation during walking with an active hip exoskeleton. Few studies examine the optimal active assistance timing of the hip exoskeleton based on muscle activation characteristics. Sixteen gender-balanced healthy adults (mean age 28.

View Article and Find Full Text PDF

Purpose: This study compared %BFUS to %BF4C in young adult athletes.

Methods: University club sport athletes (86 women, 138 men) from a variety of teams participated. ADP, DXA, and bioimpedance spectroscopy were used to measure body volume, bone mineral content, and total body water, respectively, for the 4C model.

View Article and Find Full Text PDF

: Hemodialysis patients face a high mortality risk, requiring effective clinical assessments. In these patients, muscle wasting due to protein-energy wasting (PEW) leads to increased frailty, which is strongly associated with worse outcomes, including higher mortality. As muscle mass declines, so does functional capacity, making regular assessment of both muscle mass and function critical for prognostic evaluation.

View Article and Find Full Text PDF

A comprehensive review of computational diagnostic techniques for lymphedema.

Prog Biomed Eng (Bristol)

January 2025

Amrita Vishwa Vidyapeetham, Center for Wireless Networks & Applications (WNA), Amrita Vishwa Vidyapeetham Amritapuri, Kollam, India, Kollam, 690525, INDIA.

Lymphedema is localized swelling due to lymphatic system dysfunction, often affecting arms and legs due to fluid accumulation. It occurs in 20% to 94% of patients within 2 to 5 years after breast cancer treatment, with around 20% of women developing breast cancer-related lymphedema (BCRL). This condition involves the accumulation of protein-rich fluid in interstitial spaces, leading to symptoms like swelling, pain, and reduced mobility that significantly impact quality of life.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!