Dispersive liquid-liquid microextraction based on ionic liquid coupled with high performance liquid chromatography (HPLC) and pre-column fluorescent derivatization method (IL-DLLME-HPLC-FL) was developed for the determination of eight sulfonamides (SAs). The influence of IL-DLLME parameters on extraction efficiency and the stability of derivatives of the eight SAs were investigated. The optimized experimental conditions were as follows: 40 µL [C6MIM][PF6] as extraction solvent, 0.1 mL acetone as dispersion solvents; water sample with 0% NaCl (pH 4) was extracted by dispersive liquid-liquid microextraction without ultrasonic-assistance and then derivatized for 6 h. Under the optimized experimental conditions, the results indicated that the eight sulfanilamides showed good linearities when their mass concentrations were in 0. 2-10 µg/L and 10-500 µg/L, and the linear correlation coefficients were no less than 0. 9989. The detection limits ranged from 0. 08 µg/L to 0. 5 µg/L (S/N=3). The proposed method was applied to the analysis of four water samples from different sources (tap water, lake water, Pearl River water and pond water). The relative recoveries of the SAs spiked in water samples were 87. 2% - 101. 4% with the relative standard deviations of 3. 7% - 6. 2% at three different concentration levels of 5, 50 and 200 µg/L. It is a convenient, environmental friendly method for the routine analysis of SAs in water samples.

Download full-text PDF

Source
http://dx.doi.org/10.3724/sp.j.1123.2014.08006DOI Listing

Publication Analysis

Top Keywords

dispersive liquid-liquid
12
liquid-liquid microextraction
12
water samples
12
water
9
microextraction based
8
based ionic
8
ionic liquid
8
performance liquid
8
liquid chromatography
8
determination sulfonamides
8

Similar Publications

In the present study, two most commonly used Perfluoroalkyl substances (PFASs), namely perfluorooctanoic acid (PFOA) and perfluorooctanesulfonate (PFOS), were determined in 45 tap water samples from the city of Isfahan (Iran) by dispersive liquid-liquid extraction (DLLME) and liquid chromatography-mass spectrophotometry (LC-MS) analysis. Risk assessment was also performed to determine the risk to human health. The mean concentration of PFOA was 38.

View Article and Find Full Text PDF

Reliable and sensitive analytical platform to assess dietary exposure of pigs to mycotoxins and explore potential urinary biomarkers.

Talanta

December 2024

Department of Analytical Chemistry, Faculty of Chemistry, University of Murcia, Regional Campus of International Excellence "Campus Mare Nostrum", E-30100, Murcia, Spain.

A reliable and sensitive analytical platform is proposed for the assessment of pig exposure to mycotoxins through the consumption of commercial feed. A total of 48 naturally contaminated feed and 55 urine samples collected from eight Spanish farms were analyzed using a fast and simple methodology based on solid-liquid extraction (SLE) or liquid-liquid extraction (LLE) and dispersive liquid-liquid microextraction (DLLME). High-performance liquid chromatography coupled to tandem mass spectrometry (HPLC-MS/MS) was used for the targeted analysis of 27 mycotoxins from different families in both matrices achieving limits of quantification in a range of 0.

View Article and Find Full Text PDF

Accessibility of polycyclic aromatic hydrocarbon content in fishes from the region of the 2019 oil spill on the northeast Brazil coast.

Mar Pollut Bull

December 2024

Universidade Federal de Pernambuco, Departamento de Química Fundamental, Av. Jornalista Aníbal Fernandes, s/n, Cidade Universitária, 50740-560 Recife, PE, Brazil. Electronic address:

In August 2019, Brazil experienced its largest large oil spill, which impacted extensive areas and significantly affected the northeastern region, particularly Pernambuco. Polycyclic aromatic hydrocarbons (PAHs), major oil components, are critical for assessing fish contamination risks. This study presents two sample pretreatment methods for fish samples - ultrasound-enhanced air-assisted liquid-liquid microextraction (UE-AA-LLME) for low molar mass PAHs, and matrix solid-phase dispersion for high molar mass PAHs - followed by a Gas-Chromatography coupled to Mass Spectrometry (GC-MS) detection.

View Article and Find Full Text PDF

The assessment of persistence of organic pollutants in seawater is limited by the lack of user-friendly, quick protocols for assessing one of their main sinks, degradation by marine bacteria. Here we present an experimental workflow to identify organic pollutants degradation, taking organophosphate esters flame retardants and plasticizers (OPEs-FR-PL), as a model family of synthetic chemicals released into the marine environment that are particularly widespread due to their persistence and semi-volatile nature. The proposed novel workflow combines culture-dependent techniques, solvent demulsification-dispersive liquid-liquid microextraction, with quantitative liquid chromatography coupled with mass spectrometry analyses in order to identify marine bacterial isolates with the potential to degrade OPEs-FR-PL in the marine environment.

View Article and Find Full Text PDF

This paper introduces an innovative technique for extracting pesticides from herbal infusions using a core-shell magnetic adsorbent (i.e., Cu-BTC@FeO) where achieving a notable enrichment factor for the target pesticides by coupling with a dispersive liquid-liquid microextraction method.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!