Aortic Dissection: Accurate Subintimal Flap Fenestration by Using a Reentry Catheter with Fluoroscopic Guidance-Initial Single-Institution Experience.

Radiology

From the Department of Diagnostic and Interventional Radiology (F.W., N.H., T.A.B., R.K.) and Department of Cardiothoracic and Thoracic Vascular Surgery (R.L.), University Hospital of Wuerzburg, Oberduerrbacherstr 6, D-97070 Wuerzburg, Germany; and Clinic for Radiology and Nuclear Medicine, Luebeck, Germany (J.P.G.).

Published: September 2015

Purpose: To evaluate the feasibility, effectiveness, and safety of using a commercially available reentry catheter with fluoroscopic guidance to gain controlled target lumen reentry for fenestration in patients with aortic dissection.

Materials And Methods: This retrospective study was approved by the local institutional review board; informed consent was waived. Between April 2009 and December 2013, 13 consecutive patients (10 men and three women; mean age, 51.2 years; range, 30.0-77.0 years; mean age of women, 47.0 years; range, 30.0-69.0 years; mean age of men, 52.4 years; range, 35.0-77.0 years) with aortic dissection and spinal (n = 4), renal (n = 7), mesenteric (n = 2), and/or iliofemoral (n = 9) malperfusion syndrome were included. All patients received target lumen reentry by means of balloon fenestration of the aortic dissection flap. A reentry catheter was used for fluoroscopically guided puncture of the target lumen. Technical success, clinical outcome, Stanford type of dissection, procedure time, number of fenestrations of the intimal flap per patient, necessity of additional aortic stent-graft implantation and/or placement of a bare metal stent, complications, and follow-up images were evaluated. Pre- and postinterventional systolic blood pressure gradients between the true lumen and the false lumen were compared (Wilcoxon signed-rank test). Safety of the reentry catheter maneuver was estimated with the Clopper-Pearson method.

Results: Use of the reentry catheter was technically successful in all 13 (100%) patients and clinically successful in 10 of 13 (77%) patients. Four patients had type A and nine had type B dissection. The mean clinical follow-up period was 14.2 months. Median procedure time was 71 minutes. In four patients, fenestration of the intimal flap was performed twice. Three patients underwent additional aortic stent grafting, four patients underwent placement of an iliofemoral stent, and one patient underwent placement of a carotid artery stent. Blood pressure gradients between the true lumen and the false lumen were significantly reduced (P = .0313). One patient who had a combination of syndromes died of multiorgan failure.

Conclusion: The applied commercially available reentry catheter seems to be a reliable and safe tool that may be useful for gaining target lumen reentry with reasonably good clinical outcomes.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiol.2015140520DOI Listing

Publication Analysis

Top Keywords

reentry catheter
24
target lumen
16
aortic dissection
12
lumen reentry
12
years range
12
reentry
9
patients
9
catheter fluoroscopic
8
commercially reentry
8
lumen
8

Similar Publications

Atrial flutter (AFL), defined as macro-re-entrant atrial tachycardia, is associated with debilitating symptoms, stroke, heart failure, and increased mortality. AFL is classified into typical, or cavotricuspid isthmus (CTI)-dependent, and atypical, or non-CTI-dependent. Atypical AFL is a heterogenous group of re-entrant atrial tachycardias that most commonly occur in patients with prior heart surgery or catheter ablation.

View Article and Find Full Text PDF

Background: In persistent atrial fibrillation (AF), localized extra-pulmonary vein sources may contribute to arrhythmia recurrences after pulmonary vein isolation. This in-silico study proposes a high-density sequential mapping strategy to localize such sources.

Method: Catheter repositioning was guided by repetitive conduction patterns, moving against the prevailing conduction direction (upstream) toward the sources.

View Article and Find Full Text PDF

Typical Atrial Flutter: A Practical Review.

J Cardiovasc Electrophysiol

January 2025

Cardiology Division, Geneva University Hospitals, Geneva, Switzerland.

Typical atrial flutter (AFL), defined as cavotricuspid isthmus (CTI)-dependent macro-re-entrant atrial tachycardia, often causes debilitating symptoms, and is associated with increased incidence of atrial fibrillation, stroke, heart failure, and death. Typical AFL occurs in patients with atrial remodeling and shares risk factors with atrial fibrillation. It is also common in patients with a history of prior heart surgery or catheter ablation.

View Article and Find Full Text PDF

Background: Three patients with portal hypertension and gastrointestinal bleeding due to non-cirrhotic portal vein thrombosis were treated with portal venous recanalization transjugular intrahepatic portosystemic shunt (PVR-TIPS) via a trans-splenic access.

Main Body: A "bottoms-up" retrograde puncture of the right hepatic vein was performed using a re-entry catheter to gain access to the right hepatic vein. In all patients a successful retrograde puncture of the right hepatic vein was achieved, thereby restoring the splenoportal tract.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!