Objective: To observe the effects antiarrhythmic peptide 10 (AAP10) aon acute ventricular arrhythmia and the phosphorylation state of ischemic myocardium connexin.
Methods: Acute total ischemia and partial ischemia models were established by ceasing perfusion and ligating the left anterior descending coronary artery in SD rats. The effects of AAP10 (1 mg/L) on the incidence rate of ischemia-induced ventricular arrhythmia were observed. The ischemic myocardium was sampled to detect total-Cx43 and NP-Cx43 by immunofluorescent staining and western blotting. the total-Cx43 expression was detected through image analysis system by semi-quantitative analysis.
Results: AAP10 could significantly decrease the incidence of ischemia-induced ventricular tachycardia and ventricular fibrillation. During ischemic stage, total ischemia (TI) and AAP10 total ischemia (ATI) groups were compared with partial ischemia (PI) and AAP10 partial ischemia (API) groups. The rates of incidence for arrhythmia in the ATI and API groups (10% and 0%) were lower than those in the TI and PI groups (60% and 45%). The difference between the two groups was statistically significant (P=0.019, P=0.020). The semi-quantitative analysis results of the ischemic myocardium showed that the total-Cx43 protein expression distribution areas for TI, ATI, PI and API groups were significantly decreased compared with the control group. On the other hand, the NP-Cx43 distribution areas of TI, ATI, PI and API groups were significantly increased compared with the control group (P>0.05). AAP10 could increase the total-Cx43 expression in the ischemic area and decrease the NP-Cx43 expression. Western blot results were consistent with the results of immunofluorescence staining.
Conclusions: AAP10 can significantly decrease the rate of incidence of acute ischemia-induced ventricular tachycardia and ventricular fibrillation. Acute ischemic ventricular arrhythmias may have a relationship with the decreased phosphorylation of Cx43 induced by ischemia. AAP10 may stimulate the phosphorylation of Cx43 by increasing the total-Cx43 expression and decreasing the NP-Cx43 expression in the ischemic area, so as to decrease ventricular arrhythmia.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/S1995-7645(14)60321-7 | DOI Listing |
BMJ Support Palliat Care
December 2024
Wolfson Palliative Care Research Centre, University of Hull, Hull, UK.
Implantable cardioverter defibrillators (ICDs) are implanted in increasing numbers of patients with the aim of treating ventricular arrhythmias in high-risk patients and reducing their risk of dying. Individuals are also living longer with these devices. As a result, a greater number of patients with an ICD will deteriorate either with worsening cardiac failure, another non-cardiac condition or general frailty and will have a limited prognosis.
View Article and Find Full Text PDFPacing Clin Electrophysiol
December 2024
Arrhythmia Unit, Department of Cardiology, Hospital Juan Ramón Jiménez, Huelva, Spain.
Background: Interventricular dyssynchrony derived from the classic non-physiological stimulation (n-PS) of the right ventricle (RV) is a known cause of left ventricular dysfunction (LVDys).
Methods: This was a prospective descriptive single-center study. We analyzed patients who develop LVDys with n-PS, and the results after upgrading to conduction system pacing (CSP).
ESC Heart Fail
December 2024
Department of Cardiology and Geriatrics, Kochi Medical School, Kochi University, Nankoku, Japan.
Aims: The prognostic role of high-sensitivity cardiac troponin T (hs-cTnT) as a biomarker in patients with cardiac sarcoidosis (CS) has yet to be fully determined, especially when compared with B-type natriuretic peptide (BNP).
Methods And Results: In this post-hoc analysis of the ILLUMINATE-CS (ILLUstration of the Management and prognosIs of JapaNese pATiEnts with Cardiac Sarcoidosis), which is a multicentre retrospective observational study, we analysed 103 patients (62.2 ± 10.
BMC Cardiovasc Disord
December 2024
Department of Cardiology, The First Affiliated Hospital of Dalian Medical University, Dalian, China.
Background: Delayed lead perforation is a rare complication of cardiac implantable electronic device (CIED). Clinical presentations range from completely asymptomatic to pericardial tamponade. Surgical lead extraction is recommended and transvenous lead extraction (TLE) with surgical backup is an alternative method.
View Article and Find Full Text PDFSci Rep
December 2024
Department of Physiology, School of Medicine, University of Louisville, Louisville, KY, USA.
Background -Smoking is associated with arrhythmia and sudden cardiac death, but the biological mechanisms remain unclear. In electrocardiogram (ECG) recordings abnormal durations of ventricular repolarization (QT interval), atrial depolarization (P wave), and atrioventricular depolarization (PR interval and segment), predict cardiac arrhythmia and mortality. Previous analyses of the National Health and Nutrition Examination Survey (NHANES) database for associations between smoking and ECG abnormalities were incomplete.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!