Shear-Induced Hemolysis: Species Differences.

Artif Organs

Artificial Organs Laboratory, Department of Surgery, University of Maryland School of Medicine, Baltimore County, Baltimore, MD, USA.

Published: September 2015

The nonphysiological mechanical shear stress in blood-contacting medical devices is one major factor to device-induced blood damage. Animal blood is often used to test device-induced blood damage potential of these devices due to its easy accessibility and low cost. However, the differences in shear-induced blood damage between animals and human have not been well characterized. The purpose of this study was to investigate shear-induced hemolysis of human and three commonly used preclinical evaluation animal species (ovine, porcine, and bovine) under shear conditions encountered in blood-contacting medical devices. Shear-induced hemolysis experiments were conducted using two single-pass blood-shearing devices. Driven by an externally pressurized reservoir, blood single-passes through a small annular gap in the shearing devices where the blood was exposed to a uniform high shear stress. Shear-induced hemolysis at different conditions of exposure time (0.04 to 1.5 s) and shear stress (25 to 320 Pa) was quantified for ovine, porcine, bovine, and human blood, respectively. Within these ranges of shear stress and exposure time, shear-induced hemolysis was less than 2% for the four species. The results showed that the ovine blood was more susceptible to shear-induced injury than the bovine, porcine, and human blood. The response of the porcine and bovine blood to shear was similar to the human blood. The dependence of hemolysis on shear stress level and exposure time was found to fit well the power law functional form for the four species. The coefficients of the power law models for the ovine, porcine, bovine, and human blood were derived.

Download full-text PDF

Source
http://dx.doi.org/10.1111/aor.12459DOI Listing

Publication Analysis

Top Keywords

shear-induced hemolysis
20
shear stress
20
porcine bovine
16
human blood
16
blood
12
blood damage
12
ovine porcine
12
exposure time
12
hemolysis species
8
blood-contacting medical
8

Similar Publications

Article Synopsis
  • Veno-venous extracorporeal membrane oxygenation (VV ECMO) is crucial for treating severe respiratory distress, but it often leads to complications like hemolysis and bleeding, which can increase mortality rates.
  • This study analyzed data from 580 VV ECMO patients and utilized computational modeling to assess how pump operating conditions affect hemolysis, revealing that lower pump pressures and circuit resistance minimize blood trauma.
  • The findings suggest that maintaining low circuit resistance, through using efficient oxygenators and tubing, is vital for reducing adverse effects related to ECMO support.
View Article and Find Full Text PDF

This study uses CFD methods to investigate the effects of the impeller's geometry on the hemodynamic characteristics, pump performance, and blood damage parameters, in a percutaneous microaxial Mechanical Circulatory Support (MCS) device. The numerical simulations employ the steady state Reynolds-Averaged Navier-Stokes approximation using the SST k-ω turbulent model. Three different impeller models are examined with different hub conversion angles (α = 0, 3 and 5).

View Article and Find Full Text PDF

Mitigation effect of cell exclusion on blood damage in spiral groove bearings.

J Biomech

January 2023

School of Engineering and Built Environment, Griffith University, Queensland, Australia; Critical Care Research Group, The Prince Charles Hospital, Brisbane, Australia.

Cell exclusion in spiral groove bearing (SGB) excludes red blood cells from high shear regions in the bearing gaps and potentially reduce haemolysis in rotary blood pumps. However, this mechanobiological phenomenon has been observed in ultra-low blood haematocrit only, whether it can mitigate blood damage in a clinically-relevant blood haematocrit remains unknown. This study examined whether cell exclusion in a SGB alters haemolysis and/or high-molecular-weight von Willebrand factor (HMW vWF) multimer degradation.

View Article and Find Full Text PDF

Centrifugal blood pumps have become popular for adult extracorporeal membrane oxygenation (ECMO) due to their superior blood handling and reduced thrombosis risk featured by their secondary flow paths that avoid stagnant areas. However, the high rotational speed within a centrifugal blood pump can introduce high shear stress, causing a significant shear-induced hemolysis rate. The Revolution pump, the Rotaflow pump, and the CentriMag pump are three of the leading centrifugal blood pumps on the market.

View Article and Find Full Text PDF

In vitro study of red blood cell and VWF damage in mechanical circulatory support devices based on blood-shearing platform.

Proc Inst Mech Eng H

June 2022

Artificial Organ Technology Laboratory, Bio-manufacturing Research Centre, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, China.

Blood damage induced by mechanical circulatory support devices (MCSDs) remains a significant challenge to optimal clinical care. Although researchers have been conducting in vitro studies, the major determinant of blood damage is still unclear. An optimized capillary tube blood-shearing platform with custom designed parts was constructed to investigate the influence of two flow-dependent parameters (shear stress and exposure time) on the shear-induced damage of red blood cells and von Willebrand factor (VWF).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!