Background: We compared intraocular pressure changes following laryngoscopy and intubation with conventional Macintosh blade and Airtraq optical laryngoscope.
Methods: Ninety adult patients were randomly assigned to study group or control group. Study group (n=45) - Airtraq laryngoscope was used for laryngoscopy. Control group (n=45) - conventional Macintosh laryngoscope was used for laryngoscopy. Preoperative baseline intraocular pressure was measured with Schiotz tonometer. Laryngoscopy was done as per group protocol. Intraocular pressure and haemodynamic parameters were recorded just before insertion of the device and subsequently three times at an interval of one minute after insertion of the device.
Results: Patient characteristics, baseline haemodynamic parameters and baseline intraocular pressure were comparable in the two groups. Following insertion of the endotracheal tube with Macintosh laryngoscope, there was statistically significant rise in heart rate and intraocular pressure compared to Airtraq group. There was no significant change in MAP. Eight patients in Macintosh group had tongue-lip-dental trauma during intubation, while only 2 patients received upper airway trauma in Airtraq group.
Conclusion: We conclude that Airtraq laryngoscope in comparison to Macintosh laryngoscope results in significantly fewer rises in intraocular pressure and clinically less marked increase in haemodynamic response to laryngoscopy and intubation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.bjan.2014.07.005 | DOI Listing |
Invest Ophthalmol Vis Sci
January 2025
Department of Ophthalmology, Saitama Medical University, Saitama, Japan.
Purpose: This study evaluates the effect of 6° horizontal gaze tolerance on visual field mean sensitivity (MS) in patients with glaucoma using a binocular head-mounted automated perimeter, following findings of structural changes in the posterior globe from magnetic resonance imaging and optical coherence tomography.
Methods: In this cross-sectional study, a total of 161 eyes (85 primary open-angle glaucoma [POAG] and 76 healthy) from 117 participants were included. Logistic regression and 1:1 matched analysis assessed the propensity score for glaucoma and healthy eyes, considering age, sex, and axial length as confounders.
Invest Ophthalmol Vis Sci
January 2025
Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, Seoul, Korea.
Purpose: Descemet membrane endothelial keratoplasty (DMEK) has emerged as a novel approach in corneal transplantation over the past two decades. This study aims to identify predisposing risk factors for post-DMEK ocular hypertension (OHT) and develop a preoperative predictive model for post-DMEK OHT.
Methods: Patients who underwent DMEK at Gangnam Severance Hospital between 2017 and 2024 were included in the study.
ACS Biomater Sci Eng
January 2025
Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen, Guangdong 518055, China.
Effective storage and utilization of limited donor corneal resources are in high demand to alleviate the shortage of donor corneal tissue. Here, we designed a static air-lifted organ culture system equipped with a protective coverage membrane, namely, an air-lifted OC-P system, to provide a biomimetic physiological environment for full-thickness corneal preservation. The air-lifted OC-P system features a unique collagen-based protective coverage membrane that can offer a moist, oxygen-rich environment for corneal epithelium, produce an appropriate intraocular pressure onto the cornea by gravity, and facilitate the maintenance of the organ culture medium level for nutrient supply during corneal preservation.
View Article and Find Full Text PDFClin Ophthalmol
January 2025
Department of Ophthalmology and Visual Sciences, W. K. Kellogg Eye Center, University of Michigan Medical School, Ann Arbor, MI, USA.
Purpose: To understand patient experiences using the iCare HOME tonometer through assessing ease of use, device usage patterns, proficiency, and patient comments.
Methods: We conducted a prospective survey-based cohort study of 19 patients (35 eyes) with glaucoma or glaucoma suspect diagnoses. Patients received training on home tonometer usage and were loaned the device for one week to measure intraocular pressure at home multiple times daily.
Clin Ophthalmol
January 2025
Alcon, Inc, Fort Worth, TX, USA.
Purpose: To determine the effect on intraocular pressure (IOP) of switching to a once-daily netarsudil/latanoprost fixed dose combination (FDC) from various topical treatment regimens including latanoprost monotherapy or latanoprost combined with other IOP-lowering agents for the treatment of open-angle glaucoma or ocular hypertension.
Methods: A total of 136 participants enrolled. Eligible participants were aged ≥18 years and had a current diagnosis of open-angle glaucoma or ocular hypertension.