In vivo biocompatibility of Mg implants surface modified by nanostructured merwinite/PEO.

J Mater Sci Mater Med

Biomaterials Research Group, Department of Materials Engineering, Isfahan University of Technology, 84156-83111, Isfahan, Iran,

Published: May 2015

Magnesium (Mg) alloys have been suggested as biodegradable bone implant materials due to their good intrinsic biocompatibility and great mechanical properties. Although magnesium has attractive properties as an orthopedic implant material, its quick degradation and low bioactivity may lead to the loss of mechanical integrity of the implant during the bone healing process. In this paper, we endeavor to surmount the abovementioned defects using the surface coating technique. We have recently coated AZ91 magnesium implants with merwinite (Ca3MgSi2O8) through the coupling of plasma electrolytic oxidation (PEO) and electrophoretic deposition method. In this work, we are specifically focused on the in vivo examinations of the coated implants in comparison with the uncoated one. For the in vivo experiment, the rod samples, including the uncoated and merwinite/PEO coated implants, were imbedded into the greater trochanter of rabbits. The results of the in vivo animal test indicated an improvement in biodegradability including slower implant weight loss, reduction in Mg ion released from the coated implants in the blood plasma, lesser release of hydrogen bubbles and an improvement in biocompatibility including an increase in the amount of bone formation and ultimately a mild bone inflammation after the surgery according to the histological images. In summary, proper surface treatment of magnesium implants such as silicate bioactive ceramics may improve their biocompatibility under physiological conditions to making them suitable and applicable for future clinical applications.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10856-015-5514-3DOI Listing

Publication Analysis

Top Keywords

coated implants
12
magnesium implants
8
implants
6
vivo
4
vivo biocompatibility
4
biocompatibility implants
4
implants surface
4
surface modified
4
modified nanostructured
4
nanostructured merwinite/peo
4

Similar Publications

Introduction: Chronic inflammation leading to implant failure present major challenges in orthopedics, dentistry, and reconstructive surgery. Titanium alloys, while widely used, often provoke inflammatory complications. Zinc-doped calcium phosphate (CaP) coatings offer potential to enhance implant integration by improving corrosion resistance, bioactivity, and immunocompatibility.

View Article and Find Full Text PDF

Optimizing the life of vascular access during follow-up.

J Cardiovasc Surg (Torino)

February 2025

Department of Vascular Surgery, ASST Settelaghi Universitary Teaching Hospital, University of Insubria, Varese, Italy.

Optimizing the longevity of vascular access in hemodialysis patients remains a critical aspect of patient care, given the significant role of arteriovenous fistulas (AVFs) and arteriovenous grafts (AVGs) in enabling effective dialysis. Vascular access complications, such as stenosis, thrombosis, and cannulation-related damage, continue to challenge both the functionality and the sustainability of these access points. Recent advancements underscore the importance of a robust follow-up strategy, integrating clinical evaluations with diagnostic tools like color Doppler ultrasound (CDU) and emerging interventional approaches such as drug-coated balloon (DCB) angioplasty.

View Article and Find Full Text PDF

Optical neural implants allow neuroscientists to access deep brain regions, enabling to decipher complex patterns of neural activity. In this field, the use of optical fibers is rapidly increasing, and the ability to generate high-quality metal patterns on their non-planar surface would further extend their application. Here, we propose to use alternating metal shielding and dielectric confinement to engineer the mode-division properties of tapered optical fiber neural implants.

View Article and Find Full Text PDF

In the present in vitro study, we evaluated the adhesion of an injectable platelet-rich fibrin (i-PRF) to laser-textured zirconia surfaces and their resultant friction behavior against bone tissue. Three types of zirconia surfaces were compared regarding the i-PRF coating effects: 1) grit blasted with 250-μm spherical alumina particles and acid etched with 20% hydrofluoric acid (ZLA), 2) laser textured with a random (RD) surface pattern, or 3) laser textured with a designed pattern based on 16 lines and 8 passages (L16N8). The coefficient of friction (COF) of the specimens was assessed on a reciprocating sliding pin-on-plate tribometer at 1-N normal load, 1 Hz, and a 2-mm stroke length.

View Article and Find Full Text PDF

CCN5 suppresses injury-induced vascular restenosis by inhibiting smooth muscle cell proliferation and facilitating endothelial repair via thymosin β4 and Cd9 pathway.

Eur Heart J

January 2025

State Key Laboratory of Cardiovascular Diseases and Medical Innovation Center, Shanghai Heart Failure Research Center, Shanghai East Hospital, Tongji University School of Medicine, Shanghai 200120, China.

Background And Aims: Members of the CCN matricellular protein family are crucial in various biological processes. This study aimed to characterize vascular cell-specific effects of CCN5 on neointimal formation and its role in preventing in-stent restenosis (ISR) after percutaneous coronary intervention (PCI).

Methods: Stent-implanted porcine coronary artery RNA-seq and mouse injury-induced femoral artery neointima single-cell RNA sequencing were performed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!