A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Validation of Varian's SmartAdapt® deformable image registration algorithm for clinical application. | LitMetric

Validation of Varian's SmartAdapt® deformable image registration algorithm for clinical application.

Radiat Oncol

Department of Radiation Oncology, Wellington Blood and Cancer Centre, Wellington Hospital, Private Bag 7902, 6242, Wellington, New Zealand.

Published: March 2015

Background: Re-contouring of structures on consecutive planning computed tomography (CT) images for patients that exhibit anatomical changes is elaborate and may negatively impact the turn-around time if this is required for many patients. This study was therefore initiated to validate the accuracy and usefulness of automatic contour propagation for head and neck cancer patients using SmartAdapt® which is the deformable image registration (DIR) application in Varian's Eclipse™ treatment planning system.

Methods: CT images of eight head and neck cancer patients with multiple planning CTs were registered using SmartAdapt®. The contoured structures of target volumes and OARs of the primary planning CT were deformed accordingly and subsequently compared with a reference structure set being either: 1) a structure set independently contoured by the treating Radiation Oncologist (RO), or 2) the DIR-generated structure set after being reviewed and modified by the RO.

Results: Application of DIR offered a considerable time saving for ROs in delineation of structures on CTs that were acquired mid-treatment. Quantitative analysis showed that 84% of the volume of the DIR-generated structures overlapped with the independently re-contoured structures, while 94% of the volume overlapped with the DIR-generated structures after review by the RO. This apparent intra-observer variation was further investigated resulting in the identification of several causes. Qualitative analysis showed that 92% of the DIR-generated structures either need no or only minor modification during RO reviews.

Conclusions: SmartAdapt is a powerful tool with sufficient accuracy that saves considerable time in re-contouring structures on re-CTs. However, careful review of the DIR-generated structures is mandatory, in particular in areas where tumour regression plays a role.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4465143PMC
http://dx.doi.org/10.1186/s13014-015-0372-1DOI Listing

Publication Analysis

Top Keywords

dir-generated structures
16
structure set
12
structures
9
smartadapt® deformable
8
deformable image
8
image registration
8
re-contouring structures
8
head neck
8
neck cancer
8
cancer patients
8