AI Article Synopsis

  • This paper introduces Tracer Liquid Image Velocimetry (TLIV) as a method for accurately measuring multi-layer radial flow in bioreactors, addressing the need for uniform fluid shear stress while allowing smooth variations in fluid velocity.
  • Unlike traditional Particle Image Velocimetry (PIV), TLIV uses a liquid tracer and avoids complex laser setups, employing advanced algorithms to enhance measurement accuracy in fluid dynamics experiments.
  • Results show TLIV achieves higher precision with a mean relative error of less than 2%, compared to 8.8% for PIV, making it a more accessible and cost-effective option for researchers.

Article Abstract

Background: This paper presents a Tracer Liquid Image Velocimetry (TLIV) for multi-layer radial flow in bioreactors used for cells cultivation of tissue engineering. The goal of this approach is to use simple devices to get good measuring precision, specialized for the case in which the uniform level of fluid shear stress was required while fluid velocity varied smoothly.

Methods: Compared to the widely used Particles Image Velocimetry (PIV), this method adopted a bit of liquid as tracer, without the need of laser source. Sub-pixel positioning algorithm was used to overcome the adverse effects of the tracer liquid deformation. In addition, a neighborhood smoothing algorithm was used to restrict the measurement perturbation caused by diffusion. Experiments were carried out in a parallel plates flow chamber. And mathematical models of the flow chamber and Computational Fluid Dynamics (CFD) simulation were separately employed to validate the measurement precision of TLIV.

Results: The mean relative error between the simulated and measured data can be less than 2%, while in similar validations using PIV, the error was around 8.8%.

Conclusions: TLIV avoided the contradiction between the particles' visibility and following performance with tested fluid, which is difficult to overcome in PIV. And TLIV is easier to popularize for its simple experimental condition and low cost.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4339657PMC
http://dx.doi.org/10.1186/s12938-015-0002-zDOI Listing

Publication Analysis

Top Keywords

tracer liquid
12
image velocimetry
12
liquid image
8
multi-layer radial
8
radial flow
8
flow bioreactors
8
flow chamber
8
tracer
4
velocimetry multi-layer
4
flow
4

Similar Publications

Fluorescence fluctuation spectroscopy experiments were conducted to better understand the complex mass transport dynamics of organic molecules in liquid-filled nanoporous media. Anodic aluminum oxide (AAO) membranes incorporating 10 and 20 nm diameter cylindrical pores were employed as model materials. Nile red (NR) dye was used as a fluorescent tracer.

View Article and Find Full Text PDF

Noble gas transport through geologic media has important applications in the prediction and characterization of measured gas signatures related to underground nuclear explosions (UNEs). Retarding processes such as adsorption can cause significant species fractionation of radionuclide gases, which has implications for measured and predicted signatures used to distinguish radioxenon originating from civilian nuclear facilities or from UNEs. Accounting for the effects of variable water saturation in geologic media on tracer transport is one of the most challenging aspects of modeling gas transport because there is no unifying relationship for the associated tortuosity changes between different rock types, and reactive transport processes such as adsorption that are affected by the presence of water likewise behave differently between gas species.

View Article and Find Full Text PDF

Objective: To optimize the automated radiosynthesis of the purinergic ion channel receptor 7 (P2X7R) imaging agent F-JNJ64413739 and evaluate its potential for brain imaging in osteoporotic model rats.

Methods: A more electron-deficient nitropyridine was employed as the labeling precursor to facilitate the F-labeling. The radiosynthesis was conducted on an AllinOne synthesis module, and followed by purification via high-performance liquid chromatography (HPLC).

View Article and Find Full Text PDF

Physicochemical properties of fibres can strongly impact gastric processes such as emptying and sieving. This study evaluated the influence of particle size of insoluble fibres, and gelation of soluble fibres when added to insoluble fibres, on gastric emptying of digesta phases from the proximal and distal stomach of pigs. Twenty-four boars (51.

View Article and Find Full Text PDF

Immuno-PET/CT Imaging of Trop2 with [F]AlF-RESCA-T4 Differentiates Lung Cancer from Inflammation.

J Nucl Med

December 2024

Department of Nuclear Medicine, Institute of Clinical Nuclear Medicine, School of Medicine, Renji Hospital, Shanghai Jiao Tong University, Shanghai, China;

Immuno-PET/CT imaging, a branch of molecular imaging, can noninvasively and specifically visualize biomarker expression across the body. Trophoblast cell surface antigen 2 (Trop2) is a pan-cancer biomarker and plays a crucial role in tumorigenesis through multiple signaling pathways. The study aims to develop and translate novel Trop2 single-domain antibody (sdAb) tracers for clinical use.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!