A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Long-Term Blood Alcohol Stability in Forensic Antemortem Whole Blood Samples. | LitMetric

Long-Term Blood Alcohol Stability in Forensic Antemortem Whole Blood Samples.

J Anal Toxicol

Palm Beach County Sheriff's Office, 3228 Gun Club Road, West Palm Beach, FL 33406, USA.

Published: April 2016

The effect of long-term room temperature storage on the stability of ethanol in whole blood specimens was investigated. One hundred and seventeen preserved whole blood case samples (110 of 117 with two tubes of blood in each case) were used for this study. One tube from each case was initially tested for blood alcohol concentration (BAC) for criminal driving under the influence proceedings. Cases positive for ethanol ranged in BAC from 0.023 to 0.281 g/dL. The second tube, if present, remained sealed. All blood samples were then stored at room temperature. After 5.4-10.3 years, the opened tubes were reanalyzed for BAC by the same laboratory that performed the initial testing using the same method and same instrumentation. After the same storage period, the unopened tubes were sent to a different laboratory, using a different method and different instrumentation, and reanalyzed for BAC after a total of 5.6-10.5 years of room temperature storage. Seven samples initially negative for alcohol remained negative. All samples initially positive for ethanol demonstrated a decrease in BAC over time with a statistically significant difference in loss observed based on blood sample volume and whether or not the tube had been previously opened. The decrease in BAC ranged from 0.005 to 0.234 g/dL. Tubes that were not previously opened and were more than half full demonstrated better BAC stability with 89% of these tubes demonstrating a loss of BAC between 0.01 and 0.05 g/dL.

Download full-text PDF

Source
http://dx.doi.org/10.1093/jat/bkv037DOI Listing

Publication Analysis

Top Keywords

room temperature
12
blood alcohol
8
blood samples
8
temperature storage
8
blood case
8
bac
8
positive ethanol
8
reanalyzed bac
8
method instrumentation
8
samples initially
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!