A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of muscle BOLD responses to arterial occlusion at 3 and 7 Tesla. | LitMetric

Purpose: The purpose of this study was to determine the feasibility of muscle BOLD (mBOLD) imaging at 7 Tesla (T) by comparing the changes in R2* of muscle at 3 and 7T in response to a brief period of tourniquet-induced ischemia.

Methods: Eight subjects (three male), aged 29.5 ± 6.1 years (mean ± standard deviation, SD), 167.0 ± 10.6 cm tall with a body mass of 62.0 ± 18.0 kg, participated in the study. Subjects reported to the lab on four separate occasions including a habituation session, two MRI scans, and in a subset of subjects, a session during which changes in blood flow and blood oxygenation were quantified using Doppler ultrasound (U/S) and near-infrared spectroscopy (NIRS) respectively. For statistical comparisons between 3 and 7T, R2* rate constants were calculated as R2* = 1/T2*.

Results: The mean preocclusion R2* value was greater at 7T than at 3T (60.16 ± 2.95 vs. 35.17 ± 0.35 s(-1), respectively, P < 0.001). Also, the mean ΔR2 *END and ΔR2*POST values were greater for 7T than for 3T (-2.36 ± 0.25 vs. -1.24 ± 0.39 s(-1), respectively, Table 1).

Conclusion: Muscle BOLD contrast at 7T is as much as six-fold greater than at 3T. In addition to providing greater SNR and CNR, 7T mBOLD studies may offer further advantages in the form of greater sensitivity to pathological changes in the muscle microcirculation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4609213PMC
http://dx.doi.org/10.1002/mrm.25562DOI Listing

Publication Analysis

Top Keywords

muscle bold
12
greater
5
comparison muscle
4
bold responses
4
responses arterial
4
arterial occlusion
4
occlusion tesla
4
tesla purpose
4
purpose purpose
4
purpose study
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!