Background: The management and prognosis of aortic dissection (AD) is often challenging and the use of personalised computational models is being explored as a tool to improve clinical outcome. Including vessel wall motion in such simulations can provide more realistic and potentially accurate results, but requires significant additional computational resources, as well as expertise. With clinical translation as the final aim, trade-offs between complexity, speed and accuracy are inevitable. The present study explores whether modelling wall motion is worth the additional expense in the case of AD, by carrying out fluid-structure interaction (FSI) simulations based on a sample patient case.

Methods: Patient-specific anatomical details were extracted from computed tomography images to provide the fluid domain, from which the vessel wall was extrapolated. Two-way fluid-structure interaction simulations were performed, with coupled Windkessel boundary conditions and hyperelastic wall properties. The blood was modelled using the Carreau-Yasuda viscosity model and turbulence was accounted for via a shear stress transport model. A simulation without wall motion (rigid wall) was carried out for comparison purposes.

Results: The displacement of the vessel wall was comparable to reports from imaging studies in terms of intimal flap motion and contraction of the true lumen. Analysis of the haemodynamics around the proximal and distal false lumen in the FSI model showed complex flow structures caused by the expansion and contraction of the vessel wall. These flow patterns led to significantly different predictions of wall shear stress, particularly its oscillatory component, which were not captured by the rigid wall model.

Conclusions: Through comparison with imaging data, the results of the present study indicate that the fluid-structure interaction methodology employed herein is appropriate for simulations of aortic dissection. Regions of high wall shear stress were not significantly altered by the wall motion, however, certain collocated regions of low and oscillatory wall shear stress which may be critical for disease progression were only identified in the FSI simulation. We conclude that, if patient-tailored simulations of aortic dissection are to be used as an interventional planning tool, then the additional complexity, expertise and computational expense required to model wall motion is indeed justified.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4407424PMC
http://dx.doi.org/10.1186/s12938-015-0032-6DOI Listing

Publication Analysis

Top Keywords

wall motion
20
aortic dissection
16
fluid-structure interaction
16
vessel wall
16
shear stress
16
wall
15
rigid wall
12
wall shear
12
simulations aortic
8
motion
6

Similar Publications

Background: To investigate the optimization of leadless pacemaker placement and to assess its impact on heart synchronization and tricuspid regurgitation.

Results: A clinical trial was conducted involving 53 patients who underwent leadless pacemaker implantation at the Second Affiliated Hospital of Zhejiang University School of Medicine and Hangzhou First People's Hospital between March 2022 and February 2023. Implantation site localization was determined using the 18-segment method under RAO 30° imaging.

View Article and Find Full Text PDF

Aim The study aimed to detect subtle left ventricular (LV) systolic dysfunction, reflected by abnormal global longitudinal strain (GLS), in patients with stable coronary artery disease (CAD) undergoing percutaneous coronary intervention (PCI) and to evaluate any improvement in GLS at 24 hours and six months post-PCI. Methods A total of 94 patients with stable CAD scheduled for elective PCI at our hospital were evaluated using conventional 2D echocardiography and GLS prior to the procedure. Follow-up assessments were conducted at 24 hours and six months post-PCI.

View Article and Find Full Text PDF

Aims: Recurrent acute myocardial infarction (RE-AMI) is a frequent complication after STEMI, and its association with stent thrombosis can be life-threatening. Intravenous atorvastatin (IV-atorva) administration during AMI has been shown to limit infarct size and adverse cardiac remodeling. We determined by cardiac magnetic resonance (CMR) whether the cardioprotection exerted by IV-atorva at the index AMI event translates into a better prognosis upon RE-AMI in dyslipidemic pigs.

View Article and Find Full Text PDF

Numerical modeling of conventional spin-stop agitation of liquid drug products for automated visual inspection.

Int J Pharm

January 2025

Amgen Inc., Process Development, Manufacturing Technology Advancement (MTA) Group, Thousand Oaks, CA 91320, USA. Electronic address:

The inspection of liquid-filled vials and syringes using automated visual inspection (AVI) machines is a common practice in pharmaceutical production lines. Liquid drug products are typically agitated using a spin-stop motion to detach particles from the interior surface of the containers, thereby maximizing the probability of their detection. A numerical model for an ISO 8362-1 6R glass vial was developed and validated to qualitatively assess the agitation process for a range of motion profiles, liquid drug product properties, and fill volumes.

View Article and Find Full Text PDF

Background: Severe left ventricular (LV) systolic dysfunction (ejection fraction [EF] < 30%) is a known cardiovascular risk factor and a major cause of cardioembolism. However, less severe forms of LV disease (LVD), such as mild-to-moderate LV dysfunction and LV wall motion abnormalities (LVWMAs), are considered potential minor cardiac sources in Embolic Stroke of Undetermined Source (ESUS), but their role is underexplored. This study aims to evaluate the prevalence of LVD in ESUS and its association with adverse vascular events and mortality.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!