Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The objective of this work is to assess the use of constant-wavelength synchronous fluorescence spectroscopy (SFS) in comparison to conventional fluorescence spectroscopy (CFS) for the investigation of the supramolecular host-guest interaction of β-CD with propranolol (PPL) in aqueous solutions. Scanning for the optimal Δλ at which the SFS can be performed in the presence of β-CD was examined. The results obtained revealed three distinguishable shapes for PPL using SFS that can be represented by three different Δλ values, namely 10, 40, and 100 nm. However, the effect of the β-CD concentration on the fluorescence intensity of PPL was examined using CFS and SFS of PPL at a Δλ of 10 and 100 nm. The change in the fluorescence intensity was used to calculate the equilibrium constant (Keq) for the formation of the β-CD:PPL inclusion complex by applying the Benesi-Hildebrand method. Keq values of 108, 112, and 117 M(-1) were obtained using SFS with a Δλ of 10 and 100 nm, and CFS, respectively. Further, the SFS method was successfully employed to examine the iodide quenching effect on the fluorescence intensity of PPL, where the results obtained revealed a Stern-Volmer quenching constant of 42.8 M(-1), which is in good agreement with results obtained using CFS. All results obtained using the SFS method were compared with the results obtained using the CFS method.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.saa.2015.03.128 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!