In this work an innovative, miniaturized and low cost optical chemical sensor (POF-MIP platform), based on a molecular imprinted polymer (MIP) and surface plasmon resonance in a plastic optical fiber (POF), is presented and preliminarily tested for monitoring of furfural (furan-2-carbaldehyde) in transformer oil. To this end, the optical platform was coupled to an MIP layer, highly selective for furfural. The ability of the developed sensor to directly detect furfural in the insulating oil was investigated. The detection limit of the sensor has been found to be 9 ppb, with a linear response up to about 30 ppb. However there is a sensible response up to 0.15 ppm. Because of the small linearity range, the Hill equation is suggested for the quantification. The sensor has been effectively tested in real oil samples collected from aged electrical equipment removed from service. The assessed concentration of furfural is in good agreement with that evaluated by a high pressure liquid chromatography (HLPC) method, confirming the good selectivity of the proposed sensor.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4431280PMC
http://dx.doi.org/10.3390/s150408499DOI Listing

Publication Analysis

Top Keywords

transformer oil
8
pof-mip platform
8
sensor
6
furfural
5
monitoring low
4
low levels
4
levels furfural
4
furfural power
4
power transformer
4
oil
4

Similar Publications

The application of 2D materials for detecting dissolved gas molecules is essential for identifying faults in oil-immersed transformers. This study investigates the adsorption properties of ZrCl monolayer (ML) and Pd-doped ZrCl ML with six gas molecules (CO, CO, CH, CH, CH, CH) in transformer oil using the density functional approach. The adsorption behaviour was analysed by calculating and comparing the structures, charge transfer and adsorption energies.

View Article and Find Full Text PDF

Large oil-immersed transformers have metal-enclosed shells, making it difficult to visually inspect the internal insulation condition. Visual inspection of internal defects is carried out using a self-developed micro-robot in this work. Carbon trace is the main visual characteristic of internal insulation defects.

View Article and Find Full Text PDF

Dissolved gas analysis (DGA) is an effective method for diagnosing potential faults in oil-immersed power transformers. Metal oxide semiconductor (MOS) gas sensors exhibit excellent performance. However, high operating temperatures can accelerate device aging, thereby reducing the reliability of online monitoring.

View Article and Find Full Text PDF

The modified nanoparticles can significantly improve the insulation characteristics of transformer oil. Currently, there is a lack of research on the actual motion state of particles in nanofluid to further understand the micro-mechanism of nanoparticles improving the insulation characteristics of transformer oil. In this study, the nanofluid containing 0.

View Article and Find Full Text PDF

Unlike traditional tap changers, which require transformers to be de-energized before making changes, On-Load Tap Changers (OLTCs) can adjust taps while the transformer is in service, ensuring continuous power supply during voltage regulation. OLTCs enhance grid reliability and support load balancing, reducing strain on the network and optimizing power quality. Their importance has grown as the demand for stable voltage and the integration of renewables has increased, making them vital for modern and resilient power systems.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!