A New Method to Measure the Subpubic Arch Angle Using 3-D Ultrasound.

Fetal Diagn Ther

Department of Obstetrics and Gynecology, Sant'Orsola-Malpighi University Hospital, University of Bologna, Bologna, Italy.

Published: September 2016

Objectives: The aim of this study was to assess the reproducibility of both a new contrast-enhancing technique (Oblique View eXtended Imaging, OVIX; Samsung) and the recently reported 3-D multiplanar technique (MPT) in the measurement of the subpubic angle (SPA) among a group of women at term gestation. In addition, we aimed to study the intermethod agreement between the OVIX technique and MPT.

Methods: We acquired a transperineal 3-D ultrasound volume from 155 women with a singleton uncomplicated term pregnancy before the onset of labor. Each 3-D dataset was analyzed by the MPT and OVIX algorithm. The angle formed by the lower edges of the pubic rami (SPA) was measured twice by an operator and once by another operator for each technique in order to assess intra- and interobserver reproducibility. Reproducibility and intermethod agreement were studied by means of the intraclass correlation coefficient (ICC) and Bland-Altman method.

Results: SPA measurements performed with OVIX showed high intraobserver [ICC 0.912, 95% confidence interval (CI) 0.882-0.935] and good interobserver (ICC 0.791, 95% CI 0.724-0.844) agreement, while those measured with MPT showed moderate intraobserver (ICC 0.573, 95% CI 0.457-0.670) and good interobserver (ICC 0.640, 95% CI 0.537-0.724) agreement. Whereas the intermethod analysis showed good agreement between the MPT and the OVIX techniques (ICC 0.614, 95% CI 0.414-0.757), the SPA measured by MPT were significantly wider than those measured by OVIX (125 ± 12 vs. 120 ± 11°, p = 0.006).

Conclusions: OVIX is a reliable technique for SPA measurement. MPT overestimates the SPA in comparison with OVIX. Further studies are needed to assess its clinical utility.

Download full-text PDF

Source
http://dx.doi.org/10.1159/000380947DOI Listing

Publication Analysis

Top Keywords

3-d ultrasound
8
ovix
8
intermethod agreement
8
mpt ovix
8
spa measured
8
good interobserver
8
interobserver icc
8
measured mpt
8
mpt
6
spa
6

Similar Publications

A Multi-Scale Computational Model of the Hepatic Circulation Applied to Predict the Portal Pressure After Transjugular Intrahepatic Portosystemic Shunt (TIPS).

Int J Numer Method Biomed Eng

January 2025

Hebei Provincial Key Laboratory of Portal Hypertension and Cirrhosis, Xingtai People's Hospital, Xingtai, China; Department of Radiology, Zhongda Hospital, Medical School, Southeast University, Nanjing, China.

Transjugular intrahepatic portosystemic shunt (TIPS) is a widely used surgery for portal hypertension. In clinical practice, the diameter of the stent forming a shunt is usually selected empirically, which will influence the postoperative portal pressure. Clinical studies found that inappropriate portal pressure after TIPS is responsible for poor prognosis; however, there is no scheme to predict postoperative portal pressure.

View Article and Find Full Text PDF

The Lepidopteran pest Trichoplusia ni and the parasitoid wasp Trichogramma brassicae represent a fascinating biological system, important for sustainable agricultural practices but challenging to observe. We present a nondestructive method based on micro-CT scanning technology (CT: computed tomography) for visualizing the internal parts of caterpillar embryos and of emerging parasitoids from infected eggs. Traditional methods of microscopic observation of the opaque egg contents require staining or dissection.

View Article and Find Full Text PDF

We sought to examine how resistance training (RT) status in young healthy individuals, either well resistance trained (T, n=10) or untrained (UT, n=11), affected molecular markers with leg immobilization followed by recovery RT. All participants underwent two weeks of left leg immobilization via a locking leg brace. Afterwards, all participants underwent eight weeks (3 d/week) of knee extensor focused progressive RT.

View Article and Find Full Text PDF

Evaluation of Pedicle Screw Position on Computerized Tomography Using Three-Dimensional Reconstruction Software.

Medicina (Kaunas)

December 2024

Spine Center and Department of Orthopedic Surgery, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seongnam 13620, Republic of Korea.

: Recent advances in intraoperative navigation systems have improved the accuracy of pedicle screw placement in spine surgery. However, many hospitals have limited access to these advanced technologies due to resource constraints. In such settings, postoperative computed tomography (CT) evaluation remains crucial for assessing screw placement and related potential complications.

View Article and Find Full Text PDF
Article Synopsis
  • Developed a 3-D acoustic radiation force impulse (ARFI) system for prostate imaging to identify cancerous regions and guide biopsies in one visit using a transrectal probe and 3-D visualization software.
  • The system was tested in a clinical trial comparing ARFI-guided targeted transperineal biopsies with other standard biopsy methods.
  • Results showed ARFI was less effective for lower-grade cancers but performed well for higher-grade cancers, suggesting it could enhance biopsy accuracy when combined with 2-D imaging techniques.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!