We present a 41-year-old man who underwent a cervical discarthroplasty (CDA) C5-6 procedure with an increase of the segmental range of motion from 2.8° to 6.9° and an increase in disc height from 5.8mm preoperatively to 10.4mm postoperatively with an unfavorable long-term clinical outcome. Both anterior cervical discectomy with fusion (ACDF), as well as CDA have been proven to be successful procedures in the management of cervical radiculopathy with good to excellent outcomes and low complication rates. The rationale for CDA over ACDF highlights the preservation of segmental motion and reduction of the incidence of adjacent segment disease. This case report suggests that a hypermobility syndrome and also an overcorrection of the cervical range of motion may be responsible for an unfavorable outcome after CDA.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jocn.2014.12.025DOI Listing

Publication Analysis

Top Keywords

range motion
8
cervical
5
postoperative segmental
4
segmental hypermobility
4
hypermobility cervical
4
cervical arthroplasty
4
arthroplasty pathomechanism
4
pathomechanism outcome
4
outcome failure
4
failure 41-year-old
4

Similar Publications

Purpose: While treatment modalities for Maisonneuve fractures involving the proximal third of the fibula are established, no studies to date have reported outcomes associated with syndesmotic-only fixation of middle third fibular shaft fractures. The purpose of this study was to evaluate outcomes associated with syndesmotic-only fixation in the treatment of Maisonneuve fractures involving the middle third of the fibula.

Methods: A retrospective review was conducted on 257 cases of syndesmotic ankle instability with associated fibular fractures at a level 1 trauma center between 2013 and 2023.

View Article and Find Full Text PDF

Impact of backpack load during walking: an EMG and biomechanical analysis.

Med Biol Eng Comput

January 2025

Biomedical Engineering, Bahçeşehir University, Çırağan Caddesi Osmanpaşa Mektebi Sokak No: 4-6 Beşiktaş, İstanbul, 34353, Turkey.

This study aims to understand the impact of backpack carriage, a regular activity for many, on back muscles and joint mobility during walking so that clinicians can develop strategies or products to ensure individuals' safety and well-being. Surface electromyography (EMG) and XSENS Awinda motion capture systems were used to analyze the effects of carrying a backpack (12% of body weight) on erector spinae and multifidus muscles, as well as spinal, hip, knee, and ankle joints. Subjects walked at 4 km/h on flat and inclined surfaces.

View Article and Find Full Text PDF

Fiber-based strain sensors, as wearable integrated devices, have shown substantial promise in health monitoring. However, current sensors suffer from limited tunability in sensing performance, constraining their adaptability to diverse human motions. Drawing inspiration from the structure of the spiranthes sinensis, this study introduces a unique textile wrapping technique to coil flexible silver (Ag) yarn around the surface of multifilament elastic polyurethane (PU), thereby constructing a helical structure fiber-based strain sensor.

View Article and Find Full Text PDF

Light-driven molecular rotary motors are nanometric machines able to convert light into unidirectional motions. Several types of molecular motors have been developed to better respond to light stimuli, opening new avenues for developing smart materials ranging from nanomedicine to robotics. They have great importance in the scientific research across various disciplines, but a detailed comprehension of the underlying ultrafast photophysics immediately after photo-excitation, that is, Franck-Condon region characterization, is not fully achieved yet.

View Article and Find Full Text PDF

To evaluate the clinical and radiologic outcomes of arthroscopic augmented partial repair (APR) with acellular dermal matrix versus arthroscopic superior capsular reconstruction (SCR) in massive rotator cuff tears. The study included a total of 49 patients with massive rotator cuff tears who underwent arthroscopic APR (26 patients) and SCR (23 patients) between March 2018 and June 2021. Clinical scores, visual analog scores, and range of motion were collected preoperatively and postoperatively until the last follow-up.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!