Objective: To evaluate the accuracy of two different sonographic median nerve measurement calculations in predicting carpal tunnel syndrome (CTS) severity in a study population with clinically and electrophysiologically confirmed CTS.
Methods: 643 wrists of 427 patients (325 females and 102 males, age range: 17-90 years, mean ± SD: 57.9 ± 14.7) were included with CTS diagnosis based on clinical and nerve conduction studies (NCS). Cross-sectional area (CSA) measurement of the median nerve was performed at the carpal tunnel level (CSAc) and at the pronator quadratus muscle level (CSAp). Two parameters were calculated: delta (∆-CSA), which is the difference between proximal and distal measurements, and ratio (R-CSA), calculated by dividing distal over proximal measurements.
Results: Patients were classified into mild, moderate and severe CTS based upon NCS. The mean ∆-CSA (4.2 ± 2.6, 6.95 ± 2.2 and 10.7 ± 4.9 mm(2)) and mean R-CSA (1.5 ± 0.4, 1.95 ± 0.4 and 2.4 ± 0.7) values were significantly different between all groups (p < 0.001). Optimal cut-off values for ∆-CSA and R-CSA were 6 mm(2) and 1.7, respectively, to distinguish mild from moderate disease, and 9 mm(2) and 2.2, respectively, to distinguish moderate from severe disease.
Conclusion: Threshold values for the calculated sonographic parameters ∆-CSA and R-CSA are useful in predicting CTS severity compared to NCS.
Key Points: • Two proposed parameters were calculated (∆-CSA, R-CSA) and compared to NCS. • A defined sonoanatomical proximal landmark was used for the calculation. • Both parameters showed ability to detect CTS severity comparable to NCS. • Cut-off values could be determined for both parameters.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00330-015-3649-8 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!