Cadaveric surgical simulation carries the advantage of realistic anatomy and haptic feedback but has been historically difficult to model for intraventricular approaches given the need for active flow of CSF. This feasibility study was designed to simulate intraventricular neuroendoscopic approaches and techniques by reconstituting natural CSF flow in a cadaveric model. In 10 fresh human cadavers, a simple cervical laminectomy and dural opening were made, and a 12-gauge arterial catheter was introduced. Saline was continuously perfused at physiological CSF pressures to reconstitute the subarachnoid space and ventricles. A neuroendoscope was subsequently inserted via a standard right frontal bur hole. In 8 of the 10 cadavers, adequate reconstitution and endoscopic access of the lateral and third ventricles were achieved. In 2 cadavers, ventricular access was not feasible, perhaps because of a small ventricle size and/or deteriorated tissue quality. In all 8 cadavers with successful CSF flow reconstitution and endoscopic access, identifying the foramen of Monro was possible, as was performing septum pellucidotomy and endoscopic third ventriculostomy. Furthermore, navigation of the cerebral aqueduct, fourth ventricle, prepontine cistern, and suprasellar cistern via the lamina terminalis was possible, providing a complementary educational paradigm for resident education that cannot typically be performed in live surgery. Surgical simulation plays a critical and increasingly prominent role in surgical education, particularly for techniques with steep learning curves including intraventricular neuroendoscopic procedures. This novel model provides feasible and realistic surgical simulation of neuroendoscopic intraventricular procedures and approaches.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3171/2014.10.JNS1497 | DOI Listing |
Sci Rep
December 2024
Center for Surgical Innovation and Engineering, Cedars Sinai Health System, Los Angeles, 90048, USA.
Mechanical failure of medical implants, especially in orthopedic poses a significant burden to the patients and healthcare system. The majority of the implant failures are diagnosed at very late stages and are of mechanical causes. This makes the diagnosis and screening of implant failure very challenging.
View Article and Find Full Text PDFSci Rep
December 2024
School of Gongli Hospital Medical Technology, University of Shanghai for Science and Technology, No. 516 Jungong Road, Yangpu District, Shanghai, 200093, China.
Transjugular intrahepatic portosystemic shunt (TIPS) is a widely used surgery for portal hypertensive patients, whose potential postoperative complications are closely related to the hemodynamic condition of the portal venous system. The selection of shunt position in the surgery may affect the postoperative hemodynamics; however, it is difficult for clinical studies to investigate the influence. Therefore, this study aims to employ the computational model simulating TIPS to compare the hemodynamic differences resulting from different shunt positions, and also to investigate the influences of different geometrical model simplification strategies used in the TIPS simulation.
View Article and Find Full Text PDFSci Rep
December 2024
Department of Basic Sciences, Araçatuba Dental School, São Paulo State University - UNESP, Araçatuba, 16066-840, Brazil.
Treatment of complex craniofacial deformities is still a challenge for medicine and dentistry because few approach therapies are available on the market that allow rehabilitation using 3D-printed medical devices. Thus, this study aims to create a scaffold with a morphology that simulates bone tissue, able to create a favorable environment for the development and differentiation of osteogenic cells. Moreover, its association with Plenum Guide, through cell-based tissue engineering (ASCs) for guided bone regeneration in critical rat calvarial defects.
View Article and Find Full Text PDFSci Rep
December 2024
Visual Optics Lab Antwerp (VOLANTIS), Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium.
In cataract surgery, post-surgical stability of the intraocular lens plays a major role. This study aims to explore how the size and decentration of the capsulorhexis affect intraocular lens decentration and tilt by using numerical methods. Finite element models included zonules, ciliary body, capsular bag, and an IOL with two open-loop haptics were built.
View Article and Find Full Text PDFBDJ Open
December 2024
Faculty of Odonto-Stomatology, University of Medicine and Pharmacy at Ho Chi Minh City, Ho Chi Minh City, 749000, Vietnam.
Introduction: Guided surgery for immediate anterior implants aims to reduce the time required for aesthetic and functional immediate loading. However, the limited surface area of anterior teeth for guide stabilization may affect the accuracy of implant positioning. This in vitro study evaluated the effect of the number of supporting teeth on the accuracy of immediate implants in the maxillary central incisor region.