Background: Computer modeling is used to predict inhaled aerosol deposition in the lung based on definition of the aerosol characteristics and the breathing pattern and airway anatomy of the subject. Validation of the models is limited by the lack of detailed experimental data. Three-dimensional imaging provides an opportunity to address this unmet need.

Methods: Radioactive aerosol was administered to six male asthmatic subjects on two occasions under carefully monitored input conditions. Input parameters varied in particle size, depth of breathing, and carrier gas. The aerosol distribution was measured by combined single photon emission computed tomography and x-ray computer tomography (SPECT/CT) and airway anatomy by high resolution CT. The deposition distribution was measured by both a 2D and 3D analysis and described in terms of the percentage of inhaled aerosol deposited in sections of the respiratory tract and in both spatial and anatomical subdivisions within each lung. The percentage deposition in the conducting airways was also assessed by 24 h clearance.

Results: A set of imaging data of aerosol deposition has thus been produced in which the input parameters of inhalation are well described. The results in asthmatics were compared to previous measurements in healthy controls using an identical inhalation protocol. The percentages of deposition in extra-thoracic and thoracic compartments of the airways were not significantly affected by disease, but the regional pulmonary deposition pattern was, with asthma leading to increased deposition in the conducting airways.

Conclusions: The dataset acquired in this study will be useful in validating computer models of aerosol deposition in asthmatic subjects. Asthma did not affect the fraction of inhaled aerosol depositing in the lungs, but gave rise to a more central deposition pattern. The use of 3D SPECT imaging in combination with 24 h clearance measurements enables differentiation of deposition between bronchial and bronchiolar airways.

Download full-text PDF

Source
http://dx.doi.org/10.1089/jamp.2014.1191DOI Listing

Publication Analysis

Top Keywords

aerosol deposition
16
inhaled aerosol
12
deposition
11
aerosol
9
respiratory tract
8
airway anatomy
8
asthmatic subjects
8
input parameters
8
distribution measured
8
deposition conducting
8

Similar Publications

Decadal Response of Atmospheric Inorganic Nitrogen Dry Deposition into Offshore Areas to Policy Controls and Environmental Significance.

Environ Sci Technol

December 2024

Key Laboratory of Global Change and Marine Atmospheric Chemistry, MNR, Xiamen 361001, China.

Accurately assessing the dry deposition fluxes of inorganic nitrogen aerosol (aerosol-IN) is crucial for mitigating the ecological damage caused by excessive nitrogen in oceanic equilibria. We developed a dry deposition model to assess the dry deposition fluxes of aerosol-IN into Chinese offshore areas over a decade, with the range of 2.81 × 10-1.

View Article and Find Full Text PDF

Electronic waste (e-waste) dismantling and dumpsite processes are recognized as significant sources of chlorinated paraffin (CP) exposure. This study aims to investigate the environmental occurrence and distribution of polychlorinated alkanes (PCAs-C), specifically in soil and outdoor dust samples collected from e-waste dumpsites and automobile dismantling and resale sites in Nigeria. The results revealed a widespread occurrence of PCAs across all sampled locations.

View Article and Find Full Text PDF

Mo-doped ZnO (MZO), F-doped ZnO (FZO), and Mo/F-codoped ZnO (MFZO) films have been deposited using a simple, cheap, and effective thin-film preparation route, aerosol-assisted chemical vapor deposition (AACVD). ZnO was successfully doped with Mo and/or F, confirmed by X-ray photoelectron spectroscopy (XPS) and by a decrease in unit cell parameters from X-ray diffraction (XRD). XRD also confirmed that all of the films had hexagonal wurtzite ZnO structures.

View Article and Find Full Text PDF

The aim of this study was to analyse the effect of breathing parameters, age, gender and disease status on the lung doses of the two ICS + LABA fixed combination dry powder drugs. Breathing parameters of 113 COPD patients were measured while inhaling through emptied NEXThaler® and Ellipta® inhalers and the corresponding lung doses were calculated. Lung dose of Foster® NEXThaler® was superior to the lung dose of Relvar® Ellipta® in around 85 % of the patients.

View Article and Find Full Text PDF

The IMPROVE program (Interagency Monitoring of PROtected Visual Environments) tracks long-term trends in the composition and optics of regional haze aerosols in the United States. The absorptance of red (633-nm) light is monitored by filter photometry of 24 h-integrated samples of fine particulate matter (PM 2.5).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!