Amorphous Fe73B7Si16Nb3Cu1 ribbon was crystallized rapidly by electric current heating under simultaneously applied tensile stress along the ribbon axis. As a result, strong transverse magnetic anisotropy was induced in the ribbon. Dynamic magnetic properties of the ribbons rapidly heated either under the tensile stress or without tensile stress were measured using toroidal cores. Optimal electric current heating regime that provides maximum improvement of the initial magnetic permeability and core loss was determined. Tensile stress increase from 0 to 180 MPa was shown to result in the decrease of the initial magnetic permeability down to 400 and core loss at frequencies from 0.4 to 200 kHz. Comparative analysis of magnetic properties of the cut core (with non-magnetic gap) and the cores heated under tensile stress was carried out. The magnetic properties of the latter cores are advantageous for manufacturing the reactors and linear chokes of switch-mode power supplies.