A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Computed tomography in trauma patients using iterative reconstruction: reducing radiation exposure without loss of image quality. | LitMetric

Background: Rising numbers of computed tomography (CT) examinations worldwide have led to a focus on dose reduction in the latest developments in CT technology. Iterative reconstruction (IR) models bear the potential to effectively reduce dose while maintaining adequate image quality.

Purpose: To assess the impact of adaptive statistical iterative reconstruction (ASIR) technique on dose reduction and image quality in a dedicated whole body CT (WBCT) protocol for trauma patients.

Material And Methods: A total of 122 subjects with multiple trauma was prospectively included in our study. Subjects who had to undergo a WBCT following a severe trauma were randomly assigned to two different groups: Group A was examined with an ASIR protocol for the body series (n = 64), group B (n = 58) was examined using a standard filtered back projection (FBP) protocol. Image quality was assessed both quantitatively by calculating signal-to-noise ratio (SNR) and contrast-to-noise ratios (CNRs) and qualitatively by two observers who evaluated image quality using a 5-point scale system. Applied dose was analyzed as CTDIvol (mGy), total DLP (mGyxcm), and effective dose (mSv).

Results: Applied dose for the body series in group A was about 23% lower than in group B (P < 0.05). SNR and CNRs for different tissues were not significantly different. Subjective image quality ratings were excellent and showed no significant difference, with a high inter-reader agreement.

Conclusion: ASIR contributes to a relevant dose reduction without any loss of image quality in a dedicated WBCT protocol for patients with multiple trauma.

Download full-text PDF

Source
http://dx.doi.org/10.1177/0284185115580839DOI Listing

Publication Analysis

Top Keywords

image quality
16
iterative reconstruction
12
computed tomography
8
dose reduction
8
body series
8
applied dose
8
dose
6
image
5
trauma
4
tomography trauma
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!