This study aimed to assess patient entrance surface air kerma (ESAK) during chest and abdominal X-ray procedures in screen film radiography (SFR) and computed radiography (CR) to establish dose reference levels. Patients' doses were measured in five hospitals for a total of 196 patients. ESAK was calculated from exposure parameters using DosCal software. The X-ray tube output (mGy mAs(-1)), accuracy of exposure factors, linearity and reproducibility were measured using an Unfors Xi dosimeter. The overall mean and range of ESAK during chest X-ray were 0.6 ± 0.3 (0.1-1.3) mGy, while for abdominal X-rays they were 4.0 ± 3.2 (1.3-9.2) mGy. Hospital with a CR system was found to use relatively higher doses. Dose values for abdominal X-ray procedures were comparable with previous studies. The dose for chest X-ray procedure was higher by a factor of 2-3 compared with the current international reference levels.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/rpd/ncv108 | DOI Listing |
Cureus
December 2024
Department of Diagnostic Imaging and Radiotherapy, Kulliyyah of Allied Health Sciences, International Islamic University Malaysia, Kuantan Campus, Kuantan, MYS.
In abdominal X-ray examinations, radiosensitive organs such as the gonads within or near the imaging region are at risk of radiation exposure. Minimizing the dose to these organs is crucial to reducing unnecessary radiation. This study utilized optically stimulated luminescence dosimeters (OSLDs) to measure the radiation dose to the male gonads at varying kilovoltage peak (kVp) settings while keeping the milliampere-seconds (mAs) constant across different radiographic projections.
View Article and Find Full Text PDFFed Pract
October 2024
Veterans Affairs Boston Healthcare System, West Roxbury, Massachusetts.
: A 65-year-old male veteran presented to the Veterans Affairs Boston Healthcare System (VABHS) emergency department with progressive fatigue, dyspnea on exertion, lightheadedness, and falls over the last month. New bilateral lower extremity numbness up to his knees developed in the week prior to admission and prompted him to seek care. Additional history included 2 episodes of transient loss of consciousness resulting in falls and a week of diarrhea, which had resolved.
View Article and Find Full Text PDFInt J Colorectal Dis
January 2025
Department of Surgery, Azienda Sanitaria Provinciale Crotone, 88900, Crotone, Italy.
Purpose: Chronic constipation is a common symptom. Constipation due to pelvic floor disorders remain a therapeutic challenge. Biofeedback therapy is considered as the first-choice treatment for pelvic floor disorders, whenever dedicated expertise is available.
View Article and Find Full Text PDFSci Rep
January 2025
Digestive Disease Center, CHA Bundang Medical Center, CHA University School of Medicine, CHA University, 59 Yatap-ro, Bundang-gu, Seongnam, 13496, Korea.
Endoscopic retrograde cholangiopancreatography (ERCP) training remains challenging. This study used 3D printing techniques to develop and optimize a portable ERCP training simulator and to implement basic and advanced practical techniques. Subsequently, we aimed to determine whether endoscopy trainees acquired proficiency in ERCP techniques and assess any improvements in their skill levels from using this model.
View Article and Find Full Text PDFBJS Open
December 2024
Department of Surgery, Faculty of Medicine Vajira Hospital, Navamindradhiraj University, Bangkok, Thailand.
Background: Adverse events after endoscopic retrograde cholangiopancreatography (ERCP) are rare, and post-ERCP pancreatitis is a serious adverse event. This study aimed to determine the role of aggressive intravenous hydration with lactated Ringer's solution at a specific volume with 20% human albumin before ERCP in reducing the incidence of post-ERCP pancreatitis.
Methods: This study was a single-centre randomized clinical trial.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!