Gadolinium retention in the dentate nucleus and globus pallidus is dependent on the class of contrast agent.

Radiology

From the Department of Neuroradiology, University of Heidelberg Medical Center, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany (A.R., L.D.W., O.E., S.B., P.K., S.H., M.B.); Department of Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany (A.R., H.P.S.); Department of Psychology, University of Mannheim, Mannheim, Germany (P.J.K.); and Neurology Clinic, University of Heidelberg, Heidelberg, Germany (W.W.).

Published: June 2015

Purpose: To compare changes in signal intensity (SI) ratios of the dentate nucleus (DN) and the globus pallidus (GP) to those of other structures on unenhanced T1-weighted magnetic resonance (MR) images between linear and macrocyclic gadolinium-based contrast agents (GBCAs).

Materials And Methods: The study was approved by the ethical committee of the University of Heidelberg (reference no. S-324/2014). Owing to the retrospective character of the study, the ethical committee did not require any written informed consent. Two groups of 50 patients who underwent at least six consecutive MR imaging examinations with the exclusive use of either a linear GBCA (gadopentetate dimeglumine) or a macrocyclic GBCA (gadoterate meglumine) were analyzed retrospectively. The difference in mean SI ratios of DN to pons and GP to thalamus on unenhanced T1-weighted images from the last and first examinations was calculated. One-sample and independent-sample t tests were used to assess the difference in SI ratios for both groups, and regression analysis was performed to account for potential confounders.

Results: The SI ratio difference in the linear group was greater than 0 (mean DN difference ± standard deviation, 0.0407 ± 0.0398 [P < .001]; GP, 0.0287 ± 0.0275 [P < .001]) and significantly larger (DN, P < .001 and standardized difference of 1.16; GP, P < .001 and standardized difference of 0.81) than that in the macrocyclic group, which did not differ from 0 (DN, 0.0016 ± 0.0266 [P = .680]; GP, 0.0031 ± 0.0354 [P = .538]). The SI ratio difference between the last and first examinations for the DN remained significantly different between the two groups in the regression analysis (P < .001).

Conclusion: This study indicates that an SI increase in the DN and GP on T1-weighted images is caused by serial application of the linear GBCA gadopentetate dimeglumine but not by the macrocyclic GBCA gadoterate meglumine. Clinical implications of this observation remain unclear.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiol.2015150337DOI Listing

Publication Analysis

Top Keywords

dentate nucleus
8
nucleus globus
8
globus pallidus
8
unenhanced t1-weighted
8
ethical committee
8
linear gbca
8
gbca gadopentetate
8
gadopentetate dimeglumine
8
dimeglumine macrocyclic
8
macrocyclic gbca
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!